Evaluation of an initiative to reduce radiation exposure from CT to children in a non-pediatric-focused facility
- 12 August 2015
- journal article
- Published by Springer Nature in Emergency Radiology
- Vol. 22 (6) , 631-641
Abstract
We would like to share our experience of reducing pediatric radiation exposure. Much of the recent literature regarding successes of reducing radiation exposure has come from dedicated children’s hospitals. Nonetheless, over the past two decades, there has been a considerable increase in CT imaging of children in the USA, predominantly in non-pediatric-focused facilities where the majority of children are treated. In our institution, two general hospitals with limited pediatric services, a dedicated initiative intended to reduce children’s exposure to CT radiation was started by pediatric radiologists in 2005. The initiative addressed multiple issues including eliminating multiphase studies, decreasing inappropriate scans, educating referring providers, training residents and technologists, replacing CT with ultrasound or MRI, and ensuring availability of pediatric radiologists for consultation. During the study period, the total number of CT scans decreased by 24 %. When accounting for the number of scans per visit to the emergency department (ED), the numbers of abdominal and head CT scans decreased by 37.2 and 35.2 %, respectively. For abdominal scans, the average number of phases per scan decreased from 1.70 to 1.04. Upon surveying the pediatric ED staff, it was revealed that the most influential factors on ordering of scans were daily communication with pediatric radiologists, followed by journal articles and lectures by pediatric radiologists. We concluded that a non-pediatric-focused facility can achieve dramatic reduction in CT radiation exposure to children; however, this is most effectively achieved through a dedicated, multidisciplinary process led by pediatric radiologists.Keywords
This publication has 28 references indexed in Scilit:
- Computed Tomography Use Among Children Presenting to Emergency Departments With Abdominal PainPediatrics, 2012
- Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort studyThe Lancet, 2012
- Trends in Computed Tomography Utilization in the Pediatric Emergency DepartmentPediatrics, 2012
- National Trends in Use of Computed Tomography in the Emergency DepartmentAnnals of Emergency Medicine, 2011
- Glowing in the dark: time of day as a determinant of radiographic imaging in the evaluation of abdominal pain in childrenJournal of Pediatric Surgery, 2011
- Accuracy of low-dose chest CT in intensive care patientsEmergency Radiology, 2010
- Should We be Concerned About the Rapid Increase in CT Usage?Reviews on Environmental Health, 2010
- State of the art: technologies for computed tomography dose reductionEmergency Radiology, 2009
- Increasing utilization of computed tomography in the pediatric emergency department, 2000–2006Emergency Radiology, 2007
- The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients—a white paper executive summaryPediatric Radiology, 2006