Arterial spin labeling using spatio‐temporal encoding readout for robust perfusion imaging in inhomogenous magnetic fields
Open Access
- 24 November 2022
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (3) , 1092-1101
Abstract
Purpose: To evaluate the feasibility of spatio‐temporal encoding (SPEN) readout for pseudo‐continuous ASL (pCASL) in brain, and its robustness to susceptibility artifacts as introduced by aneurysm clips.Methods: A 2D self‐refocused T2*‐compensated hybrid SPEN scheme, with super‐resolution reconstruction was implemented on a 1.5T Philips system.Q(=BWchirp*Tchirp) was varied and, the aneurysm clip‐induced artifact was evaluated in phantom (label‐images) as well as in vivo (perfusion‐weighted signal (PWS)‐maps and temporal SNR (tSNR)). In vivo results were compared to gradient‐echo EPI (GE‐EPI) and spin‐echo EPI (SE‐EPI). The dependence of tSNR on TR was evaluated separately for SPEN and SE‐EPI. SPEN withQ ˜ 75 encodes with the same off‐resonance robustness as EPI.Results: The clip‐induced artifact with SPEN decreased with increase in Q, and was smaller compared to SE‐EPI and GE‐EPI in vivo. tSNR decreased with Q and the tSNR of GE‐EPI and SE‐EPI corresponded to SPEN with a Q‐value of approximately ˜85 and ˜108, respectively. In addition, SPEN perfusion images showed a higher tSNR (p < 0.05) for TR = 4000 ms compared to TR = 2100 ms, while SE‐EPI did not. tSNR remained relatively stable when the time between SPEN‐excitation and start of the next labeling‐module was more than ˜1000 ms.Conclusion: Feasibility of combining SPEN with pCASL imaging was demonstrated, enabling cerebral perfusion measurements with a higher robustness to field inhomogeneity (Q > 75) compared to SE‐EPI and GE‐EPI. However, the SPEN chirp‐pulse saturates incoming blood, thereby reducing pCASL labeling efficiency of the next acquisition for short TRs. Future developments are needed to enable 3D scanning.Keywords
Funding Information
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (14951)
This publication has 39 references indexed in Scilit:
- Functional MRI using super-resolved spatiotemporal encodingMagnetic Resonance Imaging, 2012
- Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implantsMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Functional magnetic resonance imaging detection of vascular reactivity in cerebral amyloid angiopathyAnnals of Neurology, 2012
- Imaging of atherosclerosis: magnetic resonance imagingEuropean Heart Journal, 2011
- Functional magnetic resonance imaging using RASERNeuroImage, 2011
- Magnetic resonance imaging near metal implantsJournal of Magnetic Resonance Imaging, 2010
- Simultaneous fMRI and local field potential measurements during epileptic seizures in medetomidine‐sedated rats using raser pulse sequenceMagnetic Resonance in Medicine, 2010
- Super‐resolved spatially encoded single‐scan 2D MRIMagnetic Resonance in Medicine, 2010
- Spatially encoded NMR and the acquisition of 2D magnetic resonance images within a single scanJournal of Magnetic Resonance, 2005
- GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI techniqueMagnetic Resonance in Medicine, 1991