Robotic versus Electromagnetic Bronchoscopy for Pulmonary LesIon AssessmeNT using integrated intraprocedural imaging: study protocol for the RELIANT 2 trial
Preprint
Abstract
Background: Robotic assisted bronchoscopy (RAB) and electromagnetic navigational bronchoscopy (ENB) are two approaches to biopsy peripheral pulmonary lesions (PPLs). A recently completed cluster randomized controlled trial, RELIANT ( NCT05705544 ), showed no difference in diagnostic yield between these two modalities. The ENB platform used in RELIANT included integrated digital tomosynthesis, allowing for real-time assessment of PPL location for more precise targeting at the time of biopsy. RAB has since been integrated with cone beam computed tomography (CBCT) to accomplish the same intraprocedural correction. It is unclear if the diagnostic yield of RAB with integrated CBCT (RAB-CBCT) is superior to ENB with integrated digital tomosynthesis (ENB-DT). Methods: R obotic versus E lectromagnetic Bronchoscopy for Pulmonary L es I on A ssessme NT using integrated intraprocedural imaging (RELIANT 2) is an investigator-initiated, multicenter, open label, superiority, cluster randomized trial. At each participating institution, procedural rooms are randomly assigned to either RAB-CBCT or ENB-DT, with each procedure room-day considered a cluster. All adult patients undergoing navigational bronchoscopy for evaluation of PPL(s) are eligible. Allocation is concealed from schedulers, proceduralists, and patients until the morning of procedure when each room is randomized to a platform. The primary endpoint is the diagnostic yield, defined as the proportion of cases yielding a specific benign or malignant diagnosis per current ATS/ACCP definition. Secondary and safety endpoints include procedure duration and procedural complications. Enrollment began on November 11, 2024 and is expected to enroll approximately 440 patients in 220 clusters. Discussion: RELIANT 2 is an ongoing cluster randomized trial comparing the diagnostic yield of RAB-CBCT to that of ENB-DT in patients undergoing bronchoscopy to biopsy PPLs. This trial will help address some of the limitations of the recently published RELIANT trial. Trial Registration: The trial was registered in ClinicalTrials.gov ( NCT06654271 ) on October 21, 2024, prior to patient enrollment.Keywords
This publication has 17 references indexed in Scilit:
- Navigational Bronchoscopy or Transthoracic Needle Biopsy for Lung NodulesNew England Journal of Medicine, 2025
- Keeping Up With Technological InnovationChest, 2024
- Mobile cone‐beam computed tomography complementing shape‐sensing robotic‐assisted bronchoscopy in the small pulmonary nodule sampling: A multicentre experienceRespirology, 2023
- Guided Bronchoscopy for the Evaluation of Pulmonary LesionsChest, 2023
- Shape-Sensing Robotic-Assisted Bronchoscopy vs Digital Tomosynthesis-Corrected Electromagnetic Navigation BronchoscopyChest, 2022
- NAVIGATE 24-Month Results: Electromagnetic Navigation Bronchoscopy for Pulmonary Lesions at 37 Centers in Europe and the United StatesJournal of Thoracic Oncology, 2022
- Diagnostic Yield of Digital Tomosynthesis-assisted Navigational Bronchoscopy for Indeterminate Lung NodulesJournal of Bronchology & Interventional Pulmonology, 2021
- Improved diagnostic yield for lung nodules with digital tomosynthesis‐corrected navigational bronchoscopy: Initial experience with a novel adjunctRespirology, 2019
- The REDCap consortium: Building an international community of software platform partnersJournal of Biomedical Informatics, 2019
- Pragmatic TrialsNew England Journal of Medicine, 2016