Looping Star fMRI in Cognitive Tasks and Resting State
Open Access
- 19 February 2020
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 52 (3) , 739-751
Abstract
Background: Conventional T2*‐weighted functional magnetic resonance imaging (fMRI) is performed with echo‐planar imaging (EPI) sequences that create substantial acoustic noise. The loud acoustic noise not only affects the activation of the auditory cortex, but may also interfere with resting state and task fMRI experiments.Purpose: To demonstrate the feasibility of a novel, quiet, T2*, whole‐brain blood oxygenation level‐dependent (BOLD)‐fMRI method, termed Looping Star, compared to conventional multislice gradient‐echo EPI.Study Type: Prospective.Phantom/Subjects: Glover stability QA phantom; 10 healthy volunteers.Field Strength/Sequence: 3.0T: gradient echo (GE)‐EPI and T2* Looping Star fMRI.Assessment: Looping Star fMRI was presented and compared to GE‐EPI with a working memory (WM) task and resting state (RS) experiments. Temporal stability and acoustic measurements were obtained for both methods. Functional maps and activation accuracy were compared to evaluate the performance of the novel sequence.Statistical Tests: Mean and standard deviation values were analyzed for temporal stability and acoustic noise tests. Activation maps were assessed with one‐sample t‐tests and contrast estimates (CE). Paired t‐tests and receiver operator characteristic (ROC) were used to compare fMRI sensitivity and performance.Results: Looping Star presented a 98% reduction in sound pressure compared with GE‐EPI, with stable temporal stability (0.09% percent fluctuation), but reduced temporal signal‐to‐noise ratio (tSNR) (mean difference = 15.9%). The novel method yielded consistent activations for RS and WM (83.4% and 69.5% relative BOLD sensitivity), which increased with task difficulty (mean CE 2‐back = 0.56 vs. 0‐back = 0.08, P < 0.05). A few differences in spatial activations were found between sequences, leading to a 4–8% lower activation accuracy with Looping Star.Data Conclusion: Looping Star provides a suitable approach for whole‐brain coverage with sufficient spatiotemporal resolution and BOLD sensitivity, with only 0.5 dB above ambient noise. From the comparison with GE‐EPI, further developments of Looping Star fMRI should target increased sensitivity and spatial specificity for both RS and task experiments.Level of Evidence: 2.Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;52:739–751.Keywords
Funding Information
- BERTI, multi-partner Initial Training Network (European Union program FP7-PEOPLE-2013-ITN)
This publication has 39 references indexed in Scilit:
- Effects of scanner acoustic noise on intrinsic brain activity during auditory stimulationNeuroradiology, 2015
- fMRI-acoustic noise alters brain activation during working memory tasksNeuroImage, 2005
- Acoustic noise concerns in functional magnetic resonance imagingHuman Brain Mapping, 2003
- Acoustic noise and functional magnetic resonance imaging: Current strategies and future prospectsJournal of Magnetic Resonance Imaging, 2002
- Sound-Level Measurements and Calculations of Safe Noise Dosage During EPI at 3 TJournal of Magnetic Resonance Imaging, 2000
- Sound generation in gradient coil structures for MRIMagnetic Resonance in Medicine, 1998
- Functional MRI of brain activation induced by scanner acoustic noiseMagnetic Resonance in Medicine, 1998
- Effects of the acoustic noise of the gradient systems on fMRI: A study on auditory, motor, and visual corticesMagnetic Resonance in Medicine, 1998
- Brain magnetic resonance imaging with contrast dependent on blood oxygenation.Proceedings of the National Academy of Sciences of the United States of America, 1990
- Anxiety in patients undergoing MR imaging.Radiology, 1989