Deep residual network for off‐resonance artifact correction with application to pediatric body MRA with 3D cones
Authors:
- 22 May 2019
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 82 (4) , 1398-1411
Abstract
Purpose: To enable rapid imaging with a scan time–efficient 3D cones trajectory with a deep‐learning off‐resonance artifact correction technique.Methods: A residual convolutional neural network to correct off‐resonance artifacts (Off‐ResNet) was trained with a prospective study of pediatric MRA exams. Each exam acquired a short readout scan (1.18 ms ± 0.38) and a long readout scan (3.35 ms ± 0.74) at 3 T. Short readout scans, with longer scan times but negligible off‐resonance blurring, were used as reference images and augmented with additional off‐resonance for supervised training examples. Long readout scans, with greater off‐resonance artifacts but shorter scan time, were corrected by autofocus and Off‐ResNet and compared with short readout scans by normalized RMS error, structural similarity index, and peak SNR. Scans were also compared by scoring on 8 anatomical features by two radiologists, using analysis of variance with post hoc Tukey's test and two one‐sided t‐tests. Reader agreement was determined with intraclass correlation.Results: The total scan time for long readout scans was on average 59.3% shorter than short readout scans. Images from Off‐ResNet had superior normalized RMS error, structural similarity index, and peak SNR compared with uncorrected images across ±1 kHz off‐resonance (P < .01). The proposed method had superior normalized RMS error over −677 Hz to +1 kHz and superior structural similarity index and peak SNR over ±1 kHz compared with autofocus (P < .01). Radiologic scoring demonstrated that long readout scans corrected with Off‐ResNet were noninferior to short readout scans (P < .05).Conclusion: The proposed method can correct off‐resonance artifacts from rapid long‐readout 3D cones scans to a noninferior image quality compared with diagnostically standard short readout scans.Keywords
All Related Versions
Funding Information
- National Institutes of Health (R01 EB009690, R01 HL127039)
- Division of Graduate Education (DGE-114747)
- Stanford University (Joseph W. and Hon Mai Goodman Stanford Graduate Fe)
- GE Healthcare
- National Science Foundation
This publication has 53 references indexed in Scilit:
- Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectoryMagnetic Resonance in Medicine, 2013
- Understanding Equivalence and Noninferiority TestingJournal of General Internal Medicine, 2010
- Simultaneous B0‐ and B1+‐Map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 TMagnetic Resonance in Medicine, 2010
- Semiautomatic off‐resonance correction in spiral imagingMagnetic Resonance in Medicine, 2008
- Block regional off-resonance correction (BRORC): A fast and effective deblurring method for spiral imagingMagnetic Resonance in Medicine, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Off-resonance correction of MR imagesIEEE Transactions on Medical Imaging, 1999
- Fast Three Dimensional Magnetic Resonance ImagingMagnetic Resonance in Medicine, 1995
- Deblurring for non‐2D fourier transform magnetic resonance imagingMagnetic Resonance in Medicine, 1992