Reliability of intraoperative ultrasound in detecting tumor residual after brain diffuse glioma surgery: a systematic review and meta-analysis
- 14 August 2019
- journal article
- review article
- Published by Springer Nature in Neurosurgical Review
- Vol. 43 (5) , 1221-1233
Abstract
Intraoperative ultrasonography (iUS) is considered an accurate, safe, and cost-effective tool to estimate the extent of resection of both high-grade (HGG) and low-grade (DLGG) diffuse gliomas (DGs). However, it is currently missing an evidence-based assessment of iUS diagnostic accuracy in DGs surgery. The objective of review is to perform a systematic review and meta-analysis of the diagnostic performance of iUS in detecting tumor residue after DGs resection. A comprehensive literature search for studies published through October 2018 was performed according to PRISMA-DTA and STARD 2015 guidelines, using the following algorithm: ("ultrasound" OR "ultrasonography" OR "ultra-so*" OR "echo*" OR "eco*") AND ("brain" OR "nervous") AND ("tumor" OR "tumour" OR "lesion" OR "mass" OR "glio*" OR "GBM") AND ("surgery" OR "surgical" OR "microsurg*" OR "neurosurg*"). Pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-), and diagnostic odds ratio (DOR) of iUS in DGs were calculated. A subgroup analysis for HGGs and DLGGs was also conducted. Thirteen studies were included in the systematic review (665 DGs). Ten articles (409 DGs) were selected for the meta-analysis with the following results: sensitivity 72.2%, specificity 93.5%, LR- 0.29, LR+ 3, and DOR 9.67. Heterogeneity among studies was non-significant. Subgroup analysis demonstrates a better diagnostic performance of iUS for DLGGs compared with HGGs. iUS is an effective technique in assessing DGs resection. No significant differences are seen regarding iUS modality and transducer characteristics. Its diagnostic performance is higher in DLGGs than HGGs and could be worsened by previous treatments, surgical artifacts, and small tumor residue volumes.Keywords
This publication has 60 references indexed in Scilit:
- Gene Expression Profile of Glioblastoma Peritumoral Tissue: An Ex Vivo StudyPLOS ONE, 2013
- Ultrasound imaging in neurosurgery: approaches to minimize surgically induced image artefacts for improved resection controlActa Neurochirurgica, 2013
- Intraoperative High Frequency Ultrasound in Intracerebral High-Grade TumorsUltraschall in der Medizin - European Journal of Ultrasound, 2012
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Ultrasound-guided operations in unselected high-grade gliomas—overall results, impact of image quality and patient selectionActa Neurochirurgica, 2010
- Diffuse low-grade oligodendrogliomas extend beyond MRI-defined abnormalitiesNeurology, 2010
- Comparison of navigated 3D ultrasound findings with histopathology in subsequent phases of glioblastoma resectionActa Neurochirurgica, 2008
- Fluorescence-guided surgery with 5-aminolevulinic acid for resection of malignant glioma: a randomised controlled multicentre phase III trialThe Lancet Oncology, 2006
- Effectiveness of neuronavigation in resecting solitary intracerebral contrast-enhancing tumors: a randomized controlled trialJournal of Neurosurgery, 2006
- Evaluation of intra-operative ultrasound imaging in brain tumor resection: a prospective studyNeurological Research, 2005