Alveolar Bone Density and Width Affect Primary Implant Stability
Authors:
- 1 August 2020
- journal article
- research article
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 46 (4) , 389-395
Abstract
Primary implant stability (PIS) depends on surgical technique, implant design, and recipient bone characteristics, among other factors. Bone density (BD) can be determined in Hounsfield units (HUs) using cone beam computerized tomography (CBCT). Reliable prediction of PIS could guide treatment decisions. We assessed whether PIS was associated with recipient bone characteristics, namely, BD and alveolar ridge width (ARW), measured preoperatively by CBCT. We studied a convenience sample of 160 implants placed in 48 patients in 2016 and 2017. All underwent CBCT with a radiologic/surgical guide yielding values for ARW and BD. PIS measures used were the implant stability quotient (ISQ) from resonance frequency analysis and insertion torque (IT). IT was most influenced by the HU value at 0.5 mm outside the implant placement area, followed by the value within this area, and ISQ by the HU value at 0.5 mm outside the placement area, followed by implant placement site and apical ARW. ISQ values were significantly related to ARW in coronal (P < .05), middle (P < .01), and apical (P < .01) thirds. ISQs were higher with larger-diameter implants (P < .01). ISQ and IT were strongly correlated (P < .001). PIS in terms of ISQ and IT is positively correlated with edentulous alveolar ridge BD measured by CBCT, implying that implant stability may be predicted preoperatively. Wide alveolar ridges favored lateral PIS but did not affect rotational PIS. The most significant predictor of lateral and rotational PIS in our patients was the HU value at 0.5 mm outside the implant placement area.Keywords
This publication has 31 references indexed in Scilit:
- Implant Primary Stability Determined by Resonance Frequency AnalysisImplant Dentistry, 2012
- Does bone mineral density influence the primary stability of dental implants? A systematic reviewClinical Oral Implants Research, 2011
- A clinical study of alveolar bone quality using the fractal dimension and the implant stability quotientJournal of Periodontal & Implant Science, 2010
- Evaluation of voxel values in mandibular cancellous bone: relationship between cone‐beam computed tomography and multislice helical computed tomographyClinical Oral Implants Research, 2009
- Influence of bone density on implant stability parameters and implant success: a retrospective clinical studyBMC Oral Health, 2008
- Bivariate Evaluation of Cylinder Implant Diameter and Length: A Three‐Dimensional Finite Element AnalysisJournal of Prosthodontics, 2008
- Parameters of resonance frequency measurement values: a retrospective study of 385 ITI dental implantsClinical Oral Implants Research, 2007
- Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implantsJournal of Clinical Periodontology, 2007
- Early clinical experience on cone-beam CTJournal of Digital Imaging, 1998
- The application of three-dimensional quantitative computed tomography to the maxillofacial skeleton.Dentomaxillofacial Radiology, 1997