Pulsatile non-Newtonian haemodynamics in a 3D bifurcating abdominal aortic aneurysm model
Authors:
- 11 January 2011
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 14 (8) , 683-694
Abstract
Numerical prediction of non-Newtonian blood flow in a 3D abdominal aortic aneurysm bifurcating model is carried out. The non-Newtonian Carreau model is used to characterise the shear thinning behaviour of the human blood. A physical inlet velocity waveform incorporating a radial velocity distribution reasonably representative of a practical case configuration is employed. Case studies subject to both equal and unequal outlet pressures at iliac bifurcations are presented to display convincingly the downstream pressure influences on the flow behaviour within the aneurysm. Simulations indicate that the non-Newtonian aspects of the blood cannot at all be neglected or given a cursory treatment. The wall shear stress (WSS) is found to change significantly at both the proximal and distal ends of the aneurysm. At the peak systole, the WSS is peak around the bifurcation point, whereas the WSS becomes zero in the bifurcation point. Differential downstream pressure fields display significant effects regarding the flow evolution in the iliac arteries, whereas little or no effects are observed directly on the flow details in the aneurysm.Keywords
This publication has 22 references indexed in Scilit:
- A comparison between different asymmetric abdominal aortic aneurysm morphologies employing computational fluid–structure interaction analysisEuropean Journal of Mechanics - B/Fluids, 2007
- Compliant biomechanics of abdominal aortic aneurysms: A fluid–structure interaction studyComputers & Structures, 2007
- The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation deviceJournal of Vascular Surgery, 2006
- Numerical investigation of the non-Newtonian blood flow in a bifurcation model with a non-planar branchJournal of Biomechanics, 2004
- Non-Newtonian blood flow in human right coronary arteries: steady state simulationsJournal of Biomechanics, 2004
- The Use of the Dimensionless Womersley Number to Characterize the Unsteady Nature of Internal FlowJournal of Theoretical Biology, 1998
- BLOOD FLOW IN ARTERIESAnnual Review of Fluid Mechanics, 1997
- Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation modelJournal of Biomechanics, 1995
- Steady Flow in Abdominal Aortic Aneurysm ModelsJournal of Biomechanical Engineering, 1993
- A nonlinear analysis of pulsatile flow in arteriesJournal of Fluid Mechanics, 1972