On-Line Leak Monitoring in Fluid Pumping Systems
Authors:
- 1 January 2000
- journal article
- Published by Taylor & Francis in International Journal of Modelling and Simulation
- Vol. 20 (3) , 213-220
Abstract
In this paper, a model-based leak detection methodology for fluid pumping systems is developed. The novelty of this approach lies in modelling the leak position as a point between a real and an imaginary valve. The equations that describe the resulting dynamic system are then put into an input-output form suitable for least squares estimation. In this way, classic parameter-estimation based detection methods are applied to moving windows of system data. Computer simulation illustrates the feasibility of the method.Keywords
This publication has 4 references indexed in Scilit:
- An introduction to autonomous control systemsIEEE Control Systems, 1991
- Model-Based Architecture for High Autonomy Systems1991
- Critical Assessment of Various Leak Detection Techniques for Gas Pipeline Networks1987
- Process fault detection based on modeling and estimation methods—A surveyAutomatica, 1984