Minimum 10-Year Results of a Tapered Cementless Hip Replacement
Authors:
- Kenneth EngKEKenneth Eng
- William J. HozackWHWilliam J. Hozack
- Richard H. RothmanRRRichard H. Rothman
- 1 May 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 362 (362) , 138???144-144
Abstract
Seventy-one total hip arthroplasties with a cementless, wedge fit, cobalt chrome femoral component were reviewed in 60 patients at a minimum 10-year followup (mean, 11.5 years). For the femoral component, the mechanical failure rate was 5% and the revision rate for aseptic loosening was 0%. The mean Charnley scores for pain, function, and motion changed from preoperative mean values of 3.0, 2.7, and 3.2 to followup mean values of 5.7, 5.5, and 5.2, respectively. The followup mean Harris hip Score was 91. The incidence of thigh pain was 1.4% at 10-year followup. Ninety-five percent of femoral components showed radiologic evidence of stable, bone ingrowth fixation, whereas loosening was seen in 5% of stems. Despite the high incidence of acetabular osteolysis, no osteolysis was seen on the femoral side distal to the lesser trochanter. Nonmodularity of the femoral component led to unavoidable revision of stably fixed femoral components in seven (9.8%) hips during the revision of a loose socket. Design features (collarless, tapered, wedge fit, and circumferentially porous coated) were thought to be crucial to the superlative results with the cobalt chrome femoral component.Keywords
This publication has 18 references indexed in Scilit:
- TOTAL HIP ARTHROPLASTY WITH AN UNCEMENTED FEMORAL COMPONENTThe Journal of Bone and Joint Surgery. British volume, 1997
- Total hip arthroplasty using the Zweymuller stem implanted without cementThe Journal of Arthroplasty, 1995
- Total hip replacement with insertion of an acetabular component without cement and a femoral component with cement. Four to seven-year results.Journal of Bone and Joint Surgery, 1995
- The femoral component in total hip arthroplasty. Six to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique.Journal of Bone and Joint Surgery, 1994
- Polyethylene wear in cemented metal-backed acetabular cupsThe Journal of Bone and Joint Surgery. British volume, 1993
- The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study.Journal of Bone and Joint Surgery, 1993
- A collarless cobalt-chrome femoral component in uncemented total hip arthroplasty. Five- to eight-year follow-upThe Journal of Bone and Joint Surgery. British volume, 1992
- Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical resultsThe Journal of Bone and Joint Surgery. British volume, 1987
- Ectopic Ossification Following Total Hip ReplacementJournal of Bone and Joint Surgery, 1973
- Traumatic Arthritis of the Hip after Dislocation and Acetabular FracturesJournal of Bone and Joint Surgery, 1969