How to engineer glucose oxidase for mediated electron transfer
- 25 July 2018
- journal article
- research article
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 115 (10) , 2405-2415
Abstract
Glucose oxidase (GOx) is of high industrial interest for glucose sensing because of its high β‐d‐glucose specificity. The efficient and specific electrochemical communication between the redox center and electrodes is crucial to ensure accurate glucose determination. The efficiency of the electron transfer rates (ETR) with GOx, together with quinone diamine based mediators, is low and differs even among mediator derivatives. To design optimized enzyme–mediator couples and to describe a mediator binding model, a joint experimental and computational study was performed based on an oxygen‐independent GOx variant V7 and two quinone diimine based electron mediators (QDM‐1 and QDM‐2), which differ in polarity and size, and ferrocenemethanol (FM). A site saturation library at position 414 was screened with all three mediators and yielded four beneficial substitutions Tyr, Met, Leu, and Val. The variants showed increased mediator activity for the more polar QDM‐2 with a simultaneously decreased activity for the less polar and smaller QDM‐1 and for FM. The variant GOx V7‐I414Y exhibited the biggest change for the quinone diimine derivatives compared with V7 (QDM‐1: 55.9 U/mg V7, 33.2 U/mg V7‐I414Y; QDM‐2: 2.7 U/mg V7, 12.9 U/mg V7‐I414Y). Theoretical ETR calculated based on the Marcus theory were in good agreement with the experimental results. Molecular docking studies revealed a preferable binding of the two QD mediators directly in the active site, 3.5 Å away from the N5 atom of the flavin adenine dinucleotide (FAD) and in direct vicinity to position 414. In summary, position 414 in the active site was identified to modulate the electron shuttling from the FAD of the GOx to small water‐soluble mediators dependent on the polarity and size of residue 414 and on the polarity and size of the mediator. The presented mediator binding model offers a promising possibility for the design of optimized enzyme–mediator couples.Keywords
This publication has 74 references indexed in Scilit:
- Analytical modeling of glucose biosensors based on carbon nanotubesDiscover Nano, 2014
- Reengineered glucose oxidase for amperometric glucose determination in diabetes analyticsBiosensors and Bioelectronics, 2013
- Construction of Mutant Glucose Oxidases with Increased Dye-Mediated Dehydrogenase ActivityInternational Journal of Molecular Sciences, 2012
- Rational Redesign of Glucose Oxidase for Improved Catalytic Function and StabilityPLOS ONE, 2012
- A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and GrapheneSensors, 2012
- Electrochemical Glucose Sensors—Developments Using Electrostatic Assembly and Carbon Nanotubes for Biosensor ConstructionSensors, 2010
- AutoDock4 and AutoDockTools4: Automated docking with selective receptor flexibilityJournal of Computational Chemistry, 2009
- Development and testing of a general amber force fieldJournal of Computational Chemistry, 2004
- Fast, efficient generation of high‐quality atomic charges. AM1‐BCC model: II. Parameterization and validationJournal of Computational Chemistry, 2002
- Comparison of simple potential functions for simulating liquid waterThe Journal of Chemical Physics, 1983