Laser‐ultrasonics presents many advantages compared to conventional ultrasonics, but is, generally, considered as less sensitive. As a consequence, laser‐ultrasonics should not be adequate for ultrasonic measurements in coarse microstructure materials or measurements of large thicknesses. However, since the generated waves extend to very low frequencies, measurements in such conditions can be successfully performed if a photorefractive interferometer sensitive also to these low frequencies and properly balanced is used for detection. This is demonstrated by measurements of thicknesses up to 100 mm (4″) for various steel grades and at temperatures up to 1250 °C.