Cardiac magnetic resonance versus transthoracic echocardiography for the assessment of cardiac volumes and regional function after myocardial infarction: an intrasubject comparison using simultaneous intrasubject recordings
Open Access
- 18 August 2009
- journal article
- research article
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 38
Abstract
Background: Although echocardiography is commonly used to evaluate cardiac function after MI, CMR may provide more accurate functional assessment but has not been adequately compared with echo. The primary study objective was to compare metrics of left ventricular volumes and global and regional function determined by cardiac magnetic resonance (CMR) and echocardiography (echo) in patients (pts) with recent myocardial infarction (MI). Methods: To compare CMR with echo, 47 consecutive patients (pts 70% male; mean age = 66 ± 11 years) with MI >6 wks previously and scheduled for imaging evaluation were studied by both echo and CMR within 60 min of each other. Readers were blinded to pt information. Pearson's correlation coefficient, paired t-tests, and chi-square tests were used to compare CMR and echo measures. Further comparisons were made between pts and 30 normal controls for CMR and between pts and published normal ranges for echo. Results: Measures of volume and function correlated moderately well between CMR and echo (r = 0.54 to 0.75, all p < 0.001), but large and systematic differences were noted in absolute measurements. Echo underestimated left ventricular (LV) volumes (by 69 ml for end-diastolic, 35 ml for end-systolic volume, both p < 0.001), stroke volume (by 34 ml, p < 0.001), and LV ejection fraction (LVEF) (by 4 percentage point, p = 0.02). CMR was much more sensitive to detection of segmental wall motion abnormalities (p < 0.001). CMR comparisons with normal controls confirmed an increase in LV volumes, a decrease in LVEF, and preservation of stroke volume after MI. Conclusion: This intra subject comparison after MI found large, systematic differences between CMR and echo measures of volumes, LVEF, and wall motion abnormality despite moderate inter-modality correlations, with echo underestimating each metric. CMR also provided superior detection and quantification of segmental function after MI. Serial studies of LV function in individual patients should use the same modality.Keywords
This publication has 17 references indexed in Scilit:
- Normal Cardiac Magnetic Resonance Measurements and Interobserver Discrepancies in Volumes and Mass Using the Papillary Muscle Inclusion MethodThe Open General & Internal Medicine Journal, 2007
- Cardiovascular Function in Multi-Ethnic Study of Atherosclerosis: Normal Values by Age, Sex, and EthnicityAmerican Journal of Roentgenology, 2006
- Atrial Dimensions in Health and Left Ventricular Disease Using Cardiovascular Magnetic ResonanceJournal of Cardiovascular Magnetic Resonance, 2005
- Atrial Dimensions in Health and Left Ventricular Disease Using Cardiovascular Magnetic ResonanceJournal of Cardiovascular Magnetic Resonance, 2005
- ACC/AHA/ASE 2003 Guideline Update for the Clinical Application of Echocardiography: Summary ArticleCirculation, 2003
- Clinical Use of Cardiovascular Magnetic ResonanceCirculation, 2003
- Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequencesJournal of Magnetic Resonance Imaging, 2003
- Reproducibility of left ventricular volumes by two-dimensional echocardiographyJACC, 1983
- Apikale zweidimensionale Echokardiographie: Normalwerte für die monoplane und biplane Bestimmung der Volumina und der Ejektionsfraktion des linken VentrikelsDMW - Deutsche Medizinische Wochenschrift, 1982
- Echocardiographic assessment of a normal adult aging population.Circulation, 1977