A New Apparatus for Evaluation of Contact Erosion at the Soil–Structure Interface
Authors:
- 1 March 2013
- journal article
- research article
- Published by ASTM International in Geotechnical Testing Journal
- Vol. 36 (2) , 256-263
Abstract
The interface between clay core-wall and concrete cut-off wall is one of the weakest parts of high earth and rockfill dams. An unsuitable design can cause contact erosion at the interface or shear failure surfaces, and eventually this will harm the safety of the dam. A new soil–structure contact erosion apparatus was developed for the evaluation of contact erosion at the interface under high stress, high hydraulic head, and large shear deformation. It consists of a soil–structure model base, a seepage pressure system, a confining pressure system, an axial pressure system, and a data acquisition system. The seepage pressure system simulates the seepage erosion effect at the interface, and the maximum seepage pressure is 2.0 MPa. The confining and axial pressure systems simulate the triaxial stress state of the interface and the large shear deformation of the soil structure; the maximum confining and axial pressures are 2.0 MPa and 4.0 MPa, respectively. The data acquisition system can monitor pore pressure dissipation and settlement. Two repeatable experiments on the interface between a kind of highly plastic clay and a concrete cut-off wall were conducted to verify the scientific utility of the new apparatus. The new apparatus was found to be capable of yielding fairly consistent results in repeatable experiments. The new apparatus will prove an effective tool for studying a reasonable connection form of concrete cut-off wall and core wall in high earth and rockfill dams.Keywords
This publication has 7 references indexed in Scilit:
- Seepage Failure and Erosion of Ground with Air Bubble Dynamics2010
- Contact Erosion at the Interface between Granular Coarse Soil and Various Base Soils under Tangential Flow ConditionJournal of Geotechnical and Geoenvironmental Engineering, 2010
- True Triaxial Piping Test Apparatus for Evaluation of Piping Potential in Earth StructuresGeotechnical Testing Journal, 2010
- Critical appraisal of piping phenomena in earth damsBulletin of Engineering Geology and the Environment, 2007
- DEVELOPMENT OF SEEPAGE FAILURE ANALYSIS METHOD OF GROUND WITH SMOOTHED PARTICLE HYDRODYNAMICSSTRUCTURAL ENGINEERING / EARTHQUAKE ENGINEERING, 2006
- Seepage Failure of Sand Behind Sheet Piles—The Mechanism and Practical Approach to Analyze—Soils and Foundations, 1999
- Erosion in a granular medium interfaceJournal of Hydraulic Research, 1992