Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography
Authors:
- 7 May 2003
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (10) , 1405-1422
Abstract
This paper presents a row-action maximum likelihood algorithm (RAMLA), in which the relaxation parameter is controlled in such a way that the noise propagation from projection data to the reconstructed image is substantially independent of the access order of the input data (subsets) in each cycle of the sub-iterations. The 'subset-dependent' relaxation parameter lambda(k) (q) is expressed as lambda(k)(q) = beta0/(beta0 + q + gamma k M), where M is the number of angular views, q (0 < or = q < or = M - 1) is the access order of the angular view, k is the iteration number and beta0 and gamma are constants. The constant beta0 deals with the balance of the noise propagation and the constant gamma controls the convergence of iterations. The value of beta0 is determined from the geometrical correlation coefficients among lines of coincidence response. The proposed RAMLA using the subset-dependent (dynamic) relaxation 'dynamic RAMLA (DRAMA)' provides a reasonable signal-to-noise ratio with a satisfactory spatial resolution by a few iterations in the two-dimensional image reconstruction for PET. Dynamic OS-EM (DOSEM) has also been developed, which allows the use of a larger number of subsets (OS level) Msub without loss of signal-to-noise ratio as compared to the conventional OS-EM. DRAMA is a special case of DOSEM, where Msub = M, and it is no more profitable to use DOSEM with a smaller Msub (< M), because DRAMA provides similar performance with the fastest convergence and smallest computer burden. This paper describes the theory, algorithm and the results of the simulation studies on the performance of DRAMA and DOSEM.Keywords
This publication has 17 references indexed in Scilit:
- Fast EM-like methods for maximum "a posteriori" estimates in emission tomographyIEEE Transactions on Medical Imaging, 2001
- Application of the row action maximum likelihood algorithm with spherical basis functions to clinical PET imagingIEEE Transactions on Nuclear Science, 2001
- Fast reconstruction of 3D PET data with accurate statistical modelingIEEE Transactions on Nuclear Science, 1998
- A row-action alternative to the EM algorithm for maximizing likelihood in emission tomographyIEEE Transactions on Medical Imaging, 1996
- A factorization method for the 3D X-ray transformInverse Problems, 1995
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Algebraic reconstruction techniques can be made computationally efficient (positron emission tomography application)IEEE Transactions on Medical Imaging, 1993
- Bayesian reconstructions from emission tomography data using a modified EM algorithmIEEE Transactions on Medical Imaging, 1990
- A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priorsIEEE Transactions on Medical Imaging, 1989
- A Maximum a Posteriori Probability Expectation Maximization Algorithm for Image Reconstruction in Emission TomographyIEEE Transactions on Medical Imaging, 1987