The effect of water content on the 193 nm excimer laser ablation
Authors:
- 1 February 2002
- journal article
- research article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 30 (2) , 99-103
Abstract
Background: Water content of the corneal stroma may influence excimer laser ablation and may therefore affect residual refractive error following laser in situ keratomileusis. This study reports associations between water content of hydrogel materials and laser ablation depth. Methods: Hydrated (n = 4) and dehydrated (n = 4) hydrogel buttons of 38%, 45%, 55% and 69% water content were ablated with the Nidek EC‐5000 ArF 193 nm excimer laser, set to deliver a ‐6.00 DS curvature. Central curvature, optical quality and water content were measured before and after ablation. Hydrated buttons were rehydrated postablation and prior to measurement, to eliminate the effect of water removal during the procedure. The ablation depth per pulse was calculated. Results: The average ablation rate for fully hydrated buttons was 0.51 ± 0.17 µm. The ablation rate for hydrated materials (dry component ablation) reduced with increasing water content (P < 0.001). Dry hydrogel materials (0% water content) had an average ablation rate of 0.23 ± 0.06 µm per pulse. Conclusions: For a constant laser energy output, lower water content materials ablated to a greater extent than higher water content materials. This model provides a simple way to assess the effect of water content and dehydration on myopic laser in situ keratomileusis.Keywords
This publication has 19 references indexed in Scilit:
- VUV laser ablation of polymersApplied Surface Science, 2000
- Mechanisms of laser ablation from molecular dynamics simulations: dependence on the initial temperature and pulse durationApplied Physics A, 1999
- Excimer laser treatment of myopic astigmatism: A comparison of three ablation programsOphthalmology, 1998
- A Microscopic View of Laser AblationThe Journal of Physical Chemistry B, 1998
- Pressure Waves in Microscopic Simulations of Laser Ablation LeonidMRS Proceedings, 1998
- The corneal stroma: an inhomogeneous structureGraefe's Archive for Clinical and Experimental Ophthalmology, 1997
- Molecular Dynamics Model for Laser Ablation and Desorption of Organic SolidsThe Journal of Physical Chemistry B, 1997
- Myopic Photorefractive Keratectomy with the Excimer LaserOphthalmology, 1991
- Photorefractive keratectomy: A technique for laser refractive surgeryJournal of Cataract & Refractive Surgery, 1988
- Theory of etching of polymers by far-ultraviolet high-intensity pulsed laser- and long-term irradiationThe Journal of Physical Chemistry, 1984