Designing passive MRI‐safe implantable conducting leads with electrodes
Authors:
- Paul A. BottomleyPBPaul A. Bottomley
- Ananda KumarAKAnanda Kumar
- William A. EdelsteinWEWilliam A. Edelstein
- Justin M. AllenJAJustin M. Allen
- Parag V. KarmarkarPKParag V. Karmarkar
- 29 June 2010
- journal article
- Published by Wiley in Medical Physics
- Vol. 37 (7Part1) , 3828-3843
Abstract
Purpose: The presence of implanted electronic devices with conducting leads and electrodes are contraindicated for magnetic resonance imaging (MRI), denying many patients its potential benefits. The prime concern is MRI's radio frequency (RF) fields, which can cause elevated local specific absorption rates (SARs) and potential heat injury. The purpose of this article is to develop and compare a range of passive implantable “MRI‐safe” lead designs.Methods: Conducting leads incorporating different lengths (3–75 cm), insulation thicknesses , resistances , coiled conductors (inner diameter ), high‐impedance RF traps, and single‐coiled and triple‐coiled coaxial‐wound “billabong” leads with reversed coil sections that oppose and reduce the induced current, are investigated both experimentally using local temperature measurements, and by numerical full‐wave electromagnetic field analysis of the local SAR, in three different‐sized bioanalogous model saline‐gel phantoms at 1.5 T MRI and 4 W/kg exposure.Results: In all designs, the maximum computed 1 g average SAR and experimental temperature rise occur at the bare electrodes. Electrode heating increases with lead insulation thickness and peaks for uncoiled leads 25–50 cm long. A reasonable match between computed SAR and the point SAR estimated from thermal sensors obtained by approximating the computation volume to that of the thermal probes. Factors that maximize the impedance of leads with resistive, coiled, RF trap and billabong elements can effectively limit heating below , but folded lead configurations can be a concern. The RF trap and billabong designs can both support multiple conductors and electrodes, with billabong prototype leads also heating when tested for 3 T MRI.Conclusions: Lead insulation and length strongly affect implanted lead safety to RF exposure during MRI. Lead designs employing impedance and reversed winding sections offer hope for the development of passive, MRI‐safe, implantable conducting leads for future human use.Keywords
Funding Information
- SurgiVision, Inc.
This publication has 46 references indexed in Scilit:
- Pacemaker and ICD Generator MalfunctionsJAMA, 2006
- MRI and implanted medical devices: basic interactions with an emphasis on heatingIEEE Transactions on Device and Materials Reliability, 2005
- MRI safety: RF-induced heating near straight wiresIEEE Transactions on Magnetics, 2005
- RF heating due to conductive wires during MRI depends on the phase distribution of the transmit fieldMagnetic Resonance in Medicine, 2002
- Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging–related heating at 1.5 teslaJournal of Magnetic Resonance Imaging, 2002
- RF safety of wires in interventional MRI: Using a safety indexMagnetic Resonance in Medicine, 2001
- On the heating of linear conductive structures as guide wires and catheters in interventional MRIJournal of Magnetic Resonance Imaging, 2001
- Heating Around Intravascular Guidewires by Resonating RF WavesJournal of Magnetic Resonance Imaging, 2000
- Interactions of magnetic resonance imaging radio frequency magnetic fields with elongated medical implantsJournal of Applied Physics, 2000
- RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imagingPhysics in Medicine & Biology, 1978