Mitigation of wind‐induced motion of Milad Tower by tuned mass damper
- 2 January 2008
- journal article
- research article
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 18 (4) , 371-385
Abstract
With a height of 435 m, Milad Tower, situated in north‐west of Tehran, Iran, would be the fourth highest telecommunication tower of the world. This tower has the largest head structure among its counterparts. Preliminary studies demonstrate that the upper part of the tower has excessive wind‐induced acceleration‐related vibrations beyond human comfort limit during wind events. In this paper, the effectiveness of tuned mass damper (TMD) on the suppression of wind‐induced motion of Milad Tower is examined through mathematical analyses. The tower is modelled as a vertical linear cantilever beam, with 57 degrees of freedom. The fluctuating wind speed is assumed to be a stochastic process which is identified by an appropriate power spectral density function. Random vibration analyses were carried out to determine response statistics. The possible application of TMDs in suppressing wind‐induced motions of the tower was investigated, and a TMD was designed to be installed at the sky dome. The results clearly show that the designed TMD has a considerable influence on the suppression of the structural response of the tower below human comfort limits. The authors believe that Milad Tower can be considered as a benchmark control problem for television and telecommunication towers by the structural control community. Copyright © 2008 John Wiley & Sons, Ltd.Keywords
This publication has 20 references indexed in Scilit:
- Effects of attack angle on performance of actively controlled high-rise building motionJournal of Wind Engineering and Industrial Aerodynamics, 2005
- Seismic analysis of Tehran Telecommunication Tower using complex fractional modulusThe Structural Design of Tall Buildings, 2002
- Supplemental energy dissipation: state-of-the-art and state-of-the-practiceEngineering Structures, 2002
- Full dynamic analysis of Tehran telecommunication tower; linear and nonlinear responsesThe Structural Design of Tall Buildings, 2001
- Semi-active control systems for seismic protection of structures: a state-of-the-art reviewEngineering Structures, 1999
- Controlling buildings: a new frontier in feedbackIEEE Control Systems, 1997
- Structural Control: Past, Present, and FutureJournal of Engineering Mechanics, 1997
- Reduction of wind induced motion utilizing a tuned sloshing damperJournal of Wind Engineering and Industrial Aerodynamics, 1990
- Mitigation of wind induced motion of tall buildingsJournal of Wind Engineering and Industrial Aerodynamics, 1983
- Perception, comfort and performance criteria for human beings exposed to whole body pure yaw vibration and vibration containing yaw and translational componentsJournal of Sound and Vibration, 1981