Correlation between external and internal respiratory motion: a validation study
- 19 August 2011
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 7 (3) , 483-492
Abstract
In motion-compensated image-guided radiotherapy, accurate tracking of the target region is required. This tracking process includes building a correlation model between external surrogate motion and the motion of the target region. A novel correlation method is presented and compared with the commonly used polynomial model. The CyberKnife system (Accuray, Inc., Sunnyvale/CA) uses a polynomial correlation model to relate externally measured surrogate data (optical fibres on the patient’s chest emitting red light) to infrequently acquired internal measurements (X-ray data). A new correlation algorithm based on \({\varepsilon}\) -Support Vector Regression (SVR) was developed. Validation and comparison testing were done with human volunteers using live 3D ultrasound and externally measured infrared light-emitting diodes (IR LEDs). Seven data sets (5:03–6:27 min long) were recorded from six volunteers. Polynomial correlation algorithms were compared to the SVR-based algorithm demonstrating an average increase in root mean square (RMS) accuracy of 21.3% (0.4 mm). For three signals, the increase was more than 29% and for one signal as much as 45.6% (corresponding to more than 1.5 mm RMS). Further analysis showed the improvement to be statistically significant. The new SVR-based correlation method outperforms traditional polynomial correlation methods for motion tracking. This method is suitable for clinical implementation and may improve the overall accuracy of targeted radiotherapy.
Keywords
This publication has 23 references indexed in Scilit:
- A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoringPhysics in Medicine & Biology, 2008
- Derivation of the tumor position from external respiratory surrogates with periodical updating of the internal/external correlationPhysics in Medicine & Biology, 2007
- Adaptive prediction of internal target motion using external marker motion: a technical studyPhysics in Medicine & Biology, 2005
- The correlation between internal and external markers for abdominal tumors: Implications for respiratory gatingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I—correlating internal lung motion with skin fiducial motionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Correlation of lung tumor motion with external surrogate indicators of respirationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- A feasibility study on the prediction of tumour location in the lung from skin motionBritish Journal of Radiology, 2004
- Robotic Motion Compensation for Respiratory Movement during RadiosurgeryComputer Aided Surgery, 2000
- Robotic motion compensation for respiratory movement during radiosurgeryComputer Aided Surgery, 2000
- A survey of image registration techniquesACM Computing Surveys, 1992