Assessment of intra‐interobserver reliability of the sonographic optic nerve sheath diameter measurement
- 3 July 2015
- journal article
- Published by Wiley in The Kaohsiung Journal of Medical Sciences
- Vol. 31 (8) , 432-436
Abstract
Diagnosis and measuring the level of increase in intracranial pressure (ICP) is critical, especially for the management of trauma patients in the emergency department and intensive care unit. However, measurements are operator‐dependent as in all of the sonographic diagnoses. The aim of this study is to assess the operator variations in the measurement of optic nerve sheath diameter (ONSD). There were four emergency medicine specialists involved in the study. Each had at least 1 year of experience of ultrasound scans and performed at least 25 prior ocular scans examining the ONSD. Two measurements were made 1 week apart from both axial and longitudinal planes. Sixty healthy adults were involved in the study and every investigator obtained four measurements from each. Intra‐interobserver reliabilities were tested. The investigators performed 60 ocular ultrasounds on individual healthy adults and obtained two measurements in axial and longitudinal planes 1 week apart. Therefore, 960 measurements were analyzed. The levels of compatibilities for most of the measurements were found at acceptable levels statistically. However, it is not possible to say that there was a perfect compatibility among the sonographers according to the previously conducted reliability studies of ultrasound measurements. According to our results, it is hard to say that sonographic measurement of the ONSD is a highly reliable method both in longitudinal and transverse planes.Keywords
This publication has 19 references indexed in Scilit:
- Individual patient data systematic review and meta-analysis of optic nerve sheath diameter ultrasonography for detecting raised intracranial pressure: protocol of the ONSD research groupSystematic Reviews, 2013
- Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressureThe American Journal of Emergency Medicine, 2013
- Sonographic Optic Nerve Sheath Diameter as an Estimate of Intracranial Pressure in Adult TraumaJournal of Surgical Research, 2011
- Ocular Ultrasound to Detect Intracranial Hypertension in Trauma PatientsJournal of Trauma: Injury, Infection & Critical Care, 2011
- Making sense of Cronbach's alphaInternational Journal of Medical Education, 2011
- Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysisIntensive Care Medicine, 2011
- Ultrasonography of the optic nerve in neurocritically ill patientsActa Anaesthesiologica Scandinavica, 2011
- Intra‐ and Interobsever Reliability of Sonographic Assessment of the Optic Nerve Sheath Diameter in Healthy AdultsJournal of Neuroimaging, 2010
- A Study of Bedside Ocular Ultrasonography in the Emergency DepartmentAcademic Emergency Medicine, 2002
- Statistics notes: Cronbach's alpha: Table 1BMJ, 1997