Impact of Microstructure on Sensing Performance of Fiber-Based Iontronic Pressure Sensors: A Comparative Study
Open Access
Abstract
Highly sensitive flexible pressure sensors are crucial for wearable health monitoring and human–machine interaction. While the emerging iontronic sensors inherently offer high sensitivity, this can be further improved by engineering microstructured interfaces. In this study, we employ four different types of common fiber materials as substrates for fabricating ionic dielectric layers by a simple impregnation of ionic liquid (IL). A comparative study reveals that the porosity and microstructural architecture (e.g., fiber diameter) of the substrate material directly influences the amount of adsorbed IL and consequent sensing performance. We achieved the highest sensitivity by using a thin electrospun TPU/IL nanofiber mat (33 μm), which exhibited high sensitivities of 3.10 kPa−1, 1.85 kPa−1, and 1.02 kPa−1 in the pressure ranges of 0–200 kPa, 200–400 kPa, and 400–700 kPa, respectively. Furthermore, the sensor exhibited an excellent fast response (2.71 ms) and recovery time (8.71 ms), along with outstanding cyclic stability. This work provides valuable guidance for selecting and utilizing common fiber materials to develop high-sensitivity iontronic pressure sensors, paving the way for their practical application in next-generation wearable electronics.Keywords
Funding Information
- National Natural Science Foundation of China (62461042)
- Natural Science Foundation of Jiangxi Province (20252BAC240694)
- Jiangxi Provincial Key Laboratory of Photodetectors (2024SSY03041)
- start-up funding of Nanchang University (28170137)
This publication has 69 references indexed in Scilit:
- Machine Learning‐Enhanced Modular Ionic Skin for Broad‐Spectrum Multimodal Discriminability in Bidirectional Human–Robot InteractionAdvanced Materials, 2025
- Development of PVDF‐HFP Based Flexible Hybrid Iontronic Film for Wearable Capacitive Sensor and E‐Skin ApplicationsAdvanced Materials Technologies, 2025
- Arteriosclerosis Assessment Based on Single‐Point Fingertip Pulse Monitoring Using a Wearable Iontronic SensorAdvanced Healthcare Materials, 2023
- Ionic Flexible Mechanical Sensors: Mechanisms, Structural Engineering, Applications, and ChallengesAdvanced Sensor Research, 2023
- A Fully Printed Flexible Sensor Sheet for Simultaneous Proximity–Pressure–Temperature DetectionAdvanced Materials Technologies, 2021
- An Anti‐Freezing, Ambient‐Stable and Highly Stretchable Ionic Skin with Strong Surface Adhesion for Wearable Sensing and Soft RoboticsAdvanced Functional Materials, 2021
- First Decade of Interfacial Iontronic Sensing: From Droplet Sensors to Artificial SkinsAdvanced Materials, 2020
- Highly Sensitive Flexible Iontronic Pressure Sensor for Fingertip Pulse MonitoringAdvanced Healthcare Materials, 2020
- Highly Transparent and Flexible Iontronic Pressure Sensors Based on an Opaque to Transparent TransitionAdvanced Science, 2020
- Supercapacitive Iontronic Nanofabric SensingAdvanced Materials, 2017