In vitro CO2 9.3-μm short-pulsed laser caries prevention—effects of a newly developed laser irradiation pattern
Authors:
- 3 January 2020
- journal article
- research article
- Published by Springer Nature in Lasers in Medical Science
- Vol. 35 (4) , 979-989
Abstract
Caries prevention with different lasers has been investigated in laboratory studies and clinical pilot trials. Objective of this in vitro study was to assess whether 9.3-μm microsecond short-pulsed CO2 laser irradiation enhances enamel caries resistance without melting, with and without additional fluoride application. Seven groups of enamel, totaling 105 human enamel samples, were irradiated with 2 different carbon dioxide lasers with 2 different energy application systems (original versus spread beam; 9.3 μm wavelength, pulse repetition rate 43 Hz vs 100 Hz, fluence ranges from 1.4 to 3.9 J/cm2, pulse duration 3 μs to 18 μs). The laboratory pH-cycling was performed with or without additional fluoride, followed by cross-sectional microhardness testing. To assess caries inhibition, the mean relative mineral loss delta Z (∆Z) was determined. To evaluate for melting, scanning electron microscopy (SEM) examinations were performed. For the non-laser control groups with additional fluoride use, the relative mineral loss (ΔZ, vol% × μm) ranged between 512 ± 292 and 809 ± 297 (mean ± SD). ΔZ for the laser-irradiated samples with fluoride use ranged between 186 ± 214 and 374 ± 191, averaging a 58% ± 6% mineral loss reduction (ANOVA, P < 0.01 to P < 0.0001). For the non-laser-treated controls without additional fluoride, the mineral loss increased (ΔZ 914 ± 422 to 1224 ± 736). In contrast, the ΔZ for the laser-treated groups without additional fluoride ranged between 463 ± 190 and 594 ± 272 (P < 0.01 to P < 0.001) indicative of 50% ± 2% average reduction in mineral loss. Enhanced caries resistance was achieved by all applied fluences. Using the spread beam resulted in enhanced resistance without enamel melting as seen by SEM. CO2 9.3-μm short-pulsed laser irradiation with both laser beam configurations resulted in highly significant reduction in enamel mineral loss. Modifying the beam to a more homogenous profile will allow enamel caries resistance even without apparent enamel melting.Keywords
Funding Information
- Convergent Dental, UCSF C&G (P0524748)
This publication has 30 references indexed in Scilit:
- Performance of laser fluorescence devices and visual examination for the detection of occlusal caries in permanent molarsJournal of Biomedical Optics, 2012
- Caries inhibition in vital teeth using 9.6-μm CO2-laser irradiationJournal of Biomedical Optics, 2011
- Pulpal safety of 9.6 μm TEA CO2 laser used for caries preventionLasers in Surgery and Medicine, 2004
- Thermal and chemical modification of dentin by 9–11‐μm CO2 laser pulses of 5–100‐μs durationLasers in Surgery and Medicine, 2002
- Effect of Tooth–Bound Fluoride on Enamel Demineralization/ Remineralization in vitroCaries Research, 2000
- CO2 Laser Inhibition of Artificial Caries-like Lesion Progression in Dental EnamelJournal of Dental Research, 1998
- Combined Effects of Laser Irradiation and Chemical Inhibitors on the Dissolution of Dental EnamelCaries Research, 1992
- Increased Resistance to Artificial Caries-Like Lesions in Dentin Treated with CO2LaserCaries Research, 1992
- Comparison of Artificial Caries-Like Lesions by Quantitative Microradiography and Microhardness ProfilesCaries Research, 1983
- Lased Enamel: Ultrastructural Observations of Pulsed Carbon Dioxide Laser EffectsJournal of Dental Research, 1972