Quantification of HIV-RNA from dried blood spots using the Siemens VERSANT(R) HIV-1 RNA (kPCR) assay
Open Access
- 19 September 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 66 (12) , 2823-2826
Abstract
Simplified methods for virological monitoring in resource-limited settings are increasingly needed. We evaluated the performance of the VERSANT® HIV-1 RNA (kPCR) assay for the determination of HIV-1 viral load from dried blood spots (DBS). Assay sensitivity and correlation with plasma quantification values were assessed. A total of 98 DBS were prepared from fresh blood samples of HIV-infected patients. DBS were kept at room temperature for 6 weeks or 7 months before processing while the corresponding plasma samples were stored at −80°C. DBS were first pre-treated in a special DBS buffer. The DBS extracts and the plasma samples were then purified and amplified using the VERSANT assay reagents. In the first series of tests, performed after 6 weeks of storage, there was good correlation between quantification of viral load in plasma and in DBS (r = 0.95, P < 0.001). The detection rate in DBS was 100% when plasma levels were >1000 copies/mL. The sensitivity and specificity of the DBS assay were 88.2% [95% confidence interval (CI) 79.4–93.6] and 69.2% (95% CI 42.0–87.4), respectively. Using the 5000 copies/mL threshold (defining virological failure in resource-limited settings), both positive and negative predictive values were high (95.2% and 87.5%, respectively). After 7 months of storage there was a modest decrease in the detection rate and less significant correlations for samples with HIV-RNA <5000 copies/mL. Quantification of HIV-RNA from DBS by the VERSANT automated sample preparation and detection method can be used to diagnose virological failure in HIV-positive patients.Keywords
This publication has 10 references indexed in Scilit:
- Dried Blood Spot HIV-1 RNA Quantification Using Open Real-Time Systems in South Africa and Burkina FasoJAIDS Journal of Acquired Immune Deficiency Syndromes, 2010
- Effect of storage conditions of dried plasma and blood spots on HIV-1 RNA quantification and PCR amplification for drug resistance genotypingJournal of Antimicrobial Chemotherapy, 2010
- Measuring human immunodeficiency virus type 1 RNA loads in dried blood spot specimens using NucliSENS EasyQ HIV-1 v2.0Journal of Clinical Virology, 2010
- Correlation between HIV-1 viral load quantification in plasma, dried blood spots, and dried plasma spots using the Roche COBAS Taqman assayJournal of Clinical Virology, 2010
- Dried Blood Spots Perform Well in Viral Load Monitoring of Patients Who Receive Antiretroviral Treatment in Rural TanzaniaClinical Infectious Diseases, 2009
- Measure of Viral Load by Using the Abbott Real-Time HIV-1 Assay on Dried Blood and Plasma Spot Specimens Collected in 2 Rural Dispensaries in CameroonJAIDS Journal of Acquired Immune Deficiency Syndromes, 2009
- Dried blood spots for the diagnosis and quantitation of HIV-1: Stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in ThailandJournal of Virological Methods, 2009
- Evaluation of Filter Paper Transfer of Whole-Blood and Plasma Samples for Quantifying HIV RNA in Subjects on Antiretroviral Therapy in UgandaJAIDS Journal of Acquired Immune Deficiency Syndromes, 2007
- Multicenter Evaluation of Use of Dried Blood and Plasma Spot Specimens in Quantitative Assays for Human Immunodeficiency Virus RNA: Measurement, Precision, and RNA StabilityJournal of Clinical Microbiology, 2003
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986