Feasibility of Pulse Oximetry Screening for Critical Congenital Heart Disease at 2643-Foot Elevation
- 16 May 2013
- journal article
- research article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 34 (8) , 1803-1807
Abstract
To evaluate the feasibility of implementing a pulse oximetry screening protocol at a city of mild elevation with a specific focus on the false-positive screening rate. Pulse oximetry screening was performed according to the proposed guidelines endorsed by the American Academy of Pediatrics at a center in Tucson, AZ, at an elevation of 2,643 ft (806 m). During a 10-month period in 2012, 1069 full-term asymptomatic newborns were screened ≥24 h after birth. The mean preductal oxygen saturation was 98.5 ± 1.3 % (range 92–100 %), and the mean postductal oxygen saturation was 98.6 ± 1.3 % (range 94–100 %). Of 1,069 patients screened, 7 were excluded secondary to protocol violations, and 1 screened positive. An echocardiogram was performed on the newborn with the positive screen, and it was normal with the exception of right-to-left shunting across a patent foramen ovale. The false-positive rate was 1/1,062 or 0.094 %. The pulse oximetry screening guidelines recommended by the American Academy of Pediatrics are feasible at an elevation of 2,643 ft (806 m) with a low false-positive rate. Adjustments to the protocol are not required for centers at elevations ≤2,643 ft. Future studies at greater elevations are warranted.Keywords
This publication has 24 references indexed in Scilit:
- Feasibility of implementing pulse oximetry screening for congenital heart disease in a community hospitalJournal of Perinatology, 2012
- Pulse oximetry as a screening test for congenital heart defects in newborn infants: a cost-effectiveness analysisArchives of Disease in Childhood, 2012
- It Is Time for Routine Neonatal Screening by Pulse OximetryNeonatology, 2010
- Effectiveness of neonatal pulse oximetry screening for detection of critical congenital heart disease in daily clinical routine—results from a prospective multicenter studyEuropean Journal of Pediatrics, 2010
- Prevalence of Congenital Heart Defects in Metropolitan Atlanta, 1998-2005The Journal of Pediatrics, 2008
- Accuracy of pulse oximetry in screening for congenital heart disease in asymptomatic newborns: a systematic reviewArchives of Disease in Childhood - Fetal and Neonatal Edition, 2007
- The contribution of pulse oximetry to the early detection of congenital heart disease in newbornsEuropean Journal of Pediatrics, 2005
- Normal Values of Pulse Oximetry in Newborns at High AltitudeJournal of Tropical Pediatrics, 2005
- Reference values for pulse oximetry at high altitudeArchives of Disease in Childhood, 1998
- Pulse Oximetry: Implications for PracticeJournal of Obstetric, Gynecologic, & Neonatal Nursing, 1992