Probing glaucoma visual damage by rarebit perimetry
Authors:
Open Access
- 1 February 2005
- journal article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 89 (2) , 180-184
Abstract
Aim: To compare rarebit perimetry (RBP) with standard achromatic perimetry (SAP) in detecting early glaucomatous functional damage. Methods: 43 patients with ocular hypertension (OH), 39 with early primary open angle glaucoma (POAG), and 41 controls were considered. Visual fields were assessed using the Humphrey field analyser (HFA) 30-2 and RBP tests. Differences among the groups were evaluated using Student-Newman-Keuls and χ2 tests. Correlation between HFA and RBP parameters was assessed using the Pearson’s correlation coefficients and regression analysis. Sensitivity and specificity of RBP in detecting early glaucomatous visual damage were calculated with different algorithms. Results: RBP-mean hit rate (MHR) was respectively 88.6% (SD 4.8%) in controls; 79.1% (10.9%) in the OH group; 64.3% (13.8%) in the POAG group (differences statistically significant). Good correlation in the POAG group was found between HFA-mean deviation and RBP-MHR. Largest AROC (0.95) and optimal sensitivity (97.4%) were obtained when an abnormal RBP test was defined as having (at least 1): MHR 15 areas with a non-hit rate of >10%; ⩾2 areas with a non-hit rate of >50%; at least one area with a non-hit rate of ⩾70%. Conclusions: The RBP appeared to be a rapid, comfortable, and easily available perimetric test (requiring only a PC device), showing a high sensitivity and specificity in detecting early glaucomatous visual field defects.Keywords
This publication has 23 references indexed in Scilit:
- Visualization of localized retinal nerve fiber layer defects with the GDx with individualized and with fixed compensation of anterior segment birefringenceOphthalmology, 2003
- Spatial vision in visually asymptomatic subjects at high risk for multiple sclerosisJournal of Neurology, Neurosurgery & Psychiatry, 2003
- Visual field defects and neural losses from experimental glaucomaProgress in Retinal and Eye Research, 2002
- Frequency doubling technology perimetry for detection of glaucomatous visual field lossAmerican Journal of Ophthalmology, 2000
- Angioscotoma detection with fundus-oriented perimetryVision Research, 1999
- Neuronal death in glaucomaProgress in Retinal and Eye Research, 1999
- Prevalence of open‐angle glaucoma in central SwedenActa Ophthalmologica Scandinavica, 1996
- High-pass resolution perimetry: Central-field neuroretinal correlatesVision Research, 1995
- High‐pass resolution perimetry and age‐related loss of visual pathway neuronsActa Ophthalmologica, 1991
- Topography of ganglion cells in human retinaJournal of Comparative Neurology, 1990