A randomised, multi-centre, prospective, double blind pilot-study to evaluate safety and efficacy of the non-absorbable Optilene® Mesh Elastic versus the partly absorbable Ultrapro® Mesh for incisional hernia repair
Open Access
- 12 July 2010
- journal article
- research article
- Published by Springer Nature in BMC Surgery
- Vol. 10 (1) , 21
Abstract
Background: Randomised controlled trials with a long term follow-up (3 to 10 years) have demonstrated that mesh repair is superior to suture closure of incisional hernia with lower recurrence rates (5 to 20% versus 20 to 63%). Yet, the ideal size and material of the mesh are not defined. So far, there are few prospective studies that evaluate the influence of the mesh texture on patient's satisfaction, recurrence and complication rate. The aim of this study is to evaluate, if a non-absorbable mesh (Optilene®Mesh Elastic) will result in better health outcomes compared to a partly absorbable mesh (Ultrapro®Mesh).Methods/Design: In this prospective, randomised, double blind study, eighty patients with incisional hernia after a midline laparotomy will be included. Primary objective of this study is to investigate differences in the physical functioning score from the SF-36 questionnaire 21 days after mesh insertion. Secondary objectives include the evaluation of the patients' daily activity, pain, wound complication and other surgical complications (hematomas, seromas), and safety within six months after intervention.Discussion: This study investigates mainly from the patient perspective differences between meshes for treatment of incisional hernias. Whether partly absorbable meshes improve quality of life better than non-absorbable meshes is unclear and therefore, this trial will generate further evidence for a better treatment of patients.Trial registration: NCT00646334Keywords
This publication has 42 references indexed in Scilit:
- A lightweight, partially absorbable mesh (Ultrapro) for endoscopic hernia repair: experimental biocompatibility results obtained with a porcine modelSurgical Endoscopy, 2007
- Incisional hernia repair in Sweden 2002Hernia, 2006
- Titanium coating of a polypropylene mesh for hernia repair: Effect on biocompatibiltyHernia, 2004
- Open mesh repair of incisional hernias with significant loss of domainThe Annals of The Royal College of Surgeons of England, 2004
- In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigsSurgical Endoscopy, 2004
- Retromuskuläre Kunststoffnetz-Implantation von NarbenhernienVisceral Medicine, 2003
- Laparoskopische Narbenhernien-Reparation – Muss das Netz für die intraperitoneale Onlay-Mesh-Technik besondere Eigenschaften haben?Visceral Medicine, 2003
- Welche Anforderung sollte ein ideales Netz erfüllen?Visceral Medicine, 2003
- Repair of large midline incisional hernias with polypropylene mesh: Comparison of three operative techniquesHernia, 2003
- Functional impairment and complaints following incisional hernia repair with different polypropylene meshesHernia, 2001