Use of a Computer-aided Detection System to Detect Missed Lung Cancer at Chest Radiography
Authors:
- Charles S. WhiteCharles S. White
- Thomas FlukingerTFThomas Flukinger
- Jean JeudyJJJean Jeudy
- Joseph J. ChenJCJoseph J. Chen
- 1 July 2009
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 252 (1) , 273-281
Abstract
To study the ability of a computer-aided detection (CAD) system to detect lung cancer overlooked at initial interpretation by the radiologist. Institutional review board approval was given for this study. Patient consent was not required; a HIPAA waiver was granted because of the retrospective nature of the data collection. In patients with lung cancer diagnosed from 1995 to 2006 at two institutions, each chest radiograph obtained prior to tumor discovery was evaluated by two radiologists for an overlooked lesion. The size and location of the nodules were documented and graded for subtlety (grades 1-4, 1 = very subtle). Each radiograph with a missed lesion was analyzed by a commercial CAD system, as was the follow-up image at diagnosis. An age- and sex-matched control group was used to assess CAD false-positive rates. Missed lung cancer was found in 89 patients (age range, 51-86 years; mean age, 65 years; 80 men, nine women) on 114 radiographs. Lesion size ranged from 0.4 to 5.5 cm (mean, 1.8 cm). Lesions were most commonly peripheral (n = 63, 71%) and in upper lobes (n = 67, 75%). Lesion subtlety score was 1, 2, 3, or 4 on 43, 49, 17, and five radiographs, respectively. CAD identified 53 (47%) and 46 (52%) undetected lesions on a per-image and per-patient basis, respectively. The average size of lesions detected with CAD was 1.73 cm compared with 1.85 cm for lesions that were undetected (P = .47). A significant difference (P = .017) was found in the average subtlety score between detected lesions (score, 2.06) and undetected lesions (score, 1.68). An average of 3.9 false-positive results occurred per radiograph; an average of 2.4 false-positive results occurred per radiograph for the control group. CAD has the potential to detect approximately half of the lesions overlooked by human readers at chest radiography.Keywords
This publication has 23 references indexed in Scilit:
- Natural History of Stage I Non-Small Cell Lung CancerChest, 2007
- False-positive reduction in computer-aided diagnostic scheme for detecting nodules in chest radiographs by means of massive training artificial neural network1Academic Radiology, 2005
- Evidence for beneficial low level radiation effects and radiation hormesisBritish Journal of Radiology, 2005
- Improved Detection of Lung Nodules on Chest Radiographs Using a Commercial Computer-Aided Diagnosis SystemAmerican Journal of Roentgenology, 2004
- Effect of high sensitivity in a computerized scheme for detecting extremely subtle solitary pulmonary nodules in chest radiographs: observer performance study1Academic Radiology, 2003
- Misinterpretation of the chest x ray as a factor in the delayed diagnosis of lung cancerPostgraduate Medical Journal, 2002
- Characteristics of missed lung cancer on chest radiographs: a French experienceEuropean Radiology, 2001
- Missed Lung Cancer on Chest Radiography and Computed TomographyJournal of Thoracic Imaging, 1999
- Conventional chest radiography vs dual-energy computed radiography in the detection and characterization of pulmonary nodules.American Journal of Roentgenology, 1994
- Visual Scanning, Pattern Recognition and Decision-making in Pulmonary Nodule DetectionInvestigative Radiology, 1978