A Novel and Effective Surface Design: Conducting Polymer/β-Cyclodextrin Host–Guest System for Cholesterol Biosensor
- 3 October 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 6 (20) , 18290-18300
Abstract
The combination of supramolecules and conducting polymers (CPs) has gained much attention for the development of new immobilization matrices for biomolecules. Herein, an amperometric biosensor based on a novel conducting polymer, poly(2-(2-octyldodecyl)-4,7-di(selenoph-2-yl)-2H-benzo[d][1,2,3]triazole)) (PSBTz) and β-cyclodextrin (β-CD) for the detection of cholesterol, was constructed. The PSBTz film with β-CD was deposited on a graphite electrode by electropolymerization technique to achieve a suitable matrix for enzyme immobilization. Moreover, to justify the immobilization, alkyl chain containing conducting polymer (PSBTz) was designed, synthesized and electrochemically polymerized on the transducer surface. Alkyl chains in the structure of SBTz and hydroxyl groups of β-CD contributed to effective immobilization while protecting the suitable orientation of the biomolecule. Cholesterol oxidase (ChOx) was covalently immobilized onto the modified surface using N,N′-carbonyldiimidazole (CDI) as the cross-linking agent. After successful immobilization, amperometric biosensor responses were recorded at −0.7 V vs Ag/AgCl in phosphate buffer (pH 7.0). The apparent Michaelis-Menten constant (KMapp), maximum current (Imax), limit of detection (LOD), and sensitivity values were determined: 28.9 μM, 12.1 μA, 0.005 μM, and 5.77 μA/μM cm2, respectively. The fabricated biosensor was characterized using scanning electron microscopy (SEM) and cyclic voltammetry (CV) techniques. Finally, the prepared biosensor was successfully applied for the determination of cholesterol in blood samples.Keywords
This publication has 44 references indexed in Scilit:
- Fused structures in the polymer backbone to investigate the photovoltaic and electrochromic properties of donor–acceptor‐type conjugated polymersJournal of Polymer Science Part A: Polymer Chemistry, 2013
- Fabricating an Amperometric Cholesterol Biosensor by a Covalent Linkage between Poly(3-thiopheneacetic acid) and Cholesterol OxidaseSensors, 2009
- Poly(pyrrole) versus poly(3,4-ethylenedioxythiophene): amperometric cholesterol biosensor matricesJournal of Solid State Electrochemistry, 2008
- Zinc oxide nanoparticles-chitosan composite film for cholesterol biosensorAnalytica Chimica Acta, 2008
- Prospects of conducting polymers in biosensorsAnalytica Chimica Acta, 2006
- Novel Associative Polymer Networks Based on Cyclodextrin Inclusion CompoundsMacromolecules, 2005
- Amperometric cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on conducting polypyrrole filmsAnalytica Chimica Acta, 2004
- Host−Guest Interaction between β-Cyclodextrin and Hydrophobically Modified Poly(isobutene-alt-maleic acid) Studied by Affinity Capillary ElectrophoresisMacromolecules, 2002
- Cyclodextrins in Polymer Synthesis: Free Radical Polymerization of a N-Methacryloyl-11-aminoundecanoic Acid/β-Cyclodextrin Pseudorotaxane in an Aqueous MediumMacromolecules, 1999
- The Determination of Enzyme Dissociation ConstantsJournal of the American Chemical Society, 1934