Reproducibility and Validity of the 6-Minute Walk Test Using the Gait Real-Time Analysis Interactive Lab in Patients with COPD and Healthy Elderly
Open Access
- 8 September 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (9) , e0162444
Abstract
The 6-minute walk test (6MWT) in a regular hallway is commonly used to assess functional exercise capacity in patients with chronic obstructive pulmonary disease (COPD). However, treadmill walking might provide additional advantages over overground walking, especially if virtual reality and self-paced treadmill walking are combined. Therefore, this study aimed to assess the reproducibility and validity of the 6MWT using the Gait Real-time Analysis Interactive Lab (GRAIL) in patients with COPD and healthy elderly. Sixty-one patients with COPD and 48 healthy elderly performed two 6MWTs on the GRAIL. Patients performed two overground 6MWTs and healthy elderly performed one overground test. Differences between consecutive 6MWTs and the test conditions (GRAIL vs. overground) were analysed. Patients walked further in the second overground test (24.8 m, 95% CI 15.2–34.4 m, p<0.001) and in the second GRAIL test (26.8 m, 95% CI 13.9–39.6 m). Healthy elderly improved their second GRAIL test (49.6 m, 95% CI 37.0–62.3 m). The GRAIL 6MWT was reproducible (intra-class coefficients = 0.65–0.80). The best GRAIL 6-minute walk distance (6MWD) in patients was shorter than the best overground 6MWD (-27.3 ± 49.1 m, p<0.001). Healthy elderly walked further on the GRAIL than in the overground condition (23.6 ± 41.4 m, p<0.001). Validity of the GRAIL 6MWT was assessed and intra-class coefficient values ranging from 0.74–0.77 were found. The GRAIL is a promising system to assess the 6MWD in patients with COPD and healthy elderly. The GRAIL 6MWD seems to be more comparable to the 6MWDs assessed overground than previous studies on treadmills have reported. Furthermore, good construct validity and reproducibility were established in assessing the 6MWD using the GRAIL in patients with COPD and healthy elderly.Keywords
This publication has 24 references indexed in Scilit:
- An official European Respiratory Society/American Thoracic Society technical standard: field walking tests in chronic respiratory diseaseEuropean Respiratory Journal, 2014
- Self-paced versus fixed speed treadmill walkingGait & Posture, 2014
- Measurement of Distance Walked and Physiologic Responses to a 6-Minute Walk Test on Level Ground and on a TreadmillJournal of Geriatric Physical Therapy, 2012
- Hallway Versus Treadmill 6-Minute-Walk Tests in Patients With Chronic Obstructive Pulmonary DiseaseRespiratory Care, 2009
- Modifying Track Layout From Straight to Circular Has a Modest Effect on the 6-min Walk DistanceChest, 2008
- International variation in the prevalence of COPD (The BOLD Study): a population-based prevalence studyThe Lancet, 2007
- Systemic effects of chronic obstructive pulmonary diseaseEuropean Respiratory Journal, 2003
- Chronic obstructive pulmonary disease * 5: Systemic effects of COPDThorax, 2002
- ATS Statement: Guidelines for the Six-Minute Walk TestAmerican Journal of Respiratory and Critical Care Medicine, 2002
- Comparison of Hallway and Treadmill Six-minute Walk TestsAmerican Journal of Respiratory and Critical Care Medicine, 1999