Association Between Defibrillation Using LIFEPAK 15 or ZOLL X Series and Survival Outcomes in Out‐of‐Hospital Cardiac Arrest: A Nationwide Cohort Study
Authors:
- Carsten MeilandtCMCarsten Meilandt
- Mette QvortrupMQMette Qvortrup
- Morten Thingemann BøtkerMBMorten Thingemann Bøtker
- Fredrik FolkeFFFredrik Folke
- Lars BorupLBLars Borup
- Helle Collatz ChristensenHCHelle Collatz Christensen
- Louise MillingLMLouise Milling
- Kasper G. LauridsenKLKasper G. Lauridsen
- Bo LøfgrenBLBo Løfgren
Open Access
- 2 April 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (7) , e033913
Abstract
Background: Defibrillation is essential for achieving return of spontaneous circulation (ROSC) following out‐of‐hospital cardiac arrest (OHCA) with shockable rhythms. This study aimed to investigate if the type of defibrillator used was associated with ROSC in OHCA. Methods and Results: This study included adult patients with OHCA from the Danish Cardiac Arrest Registry from 2016 to 2021 with at least 1 defibrillation by the emergency medical services. We used multivariable logistic regression and a difference‐in‐difference analysis, including all patients with or without emergency medical services shock to assess the causal inference of using the different defibrillator models (LIFEPAK or ZOLL) for OHCA defibrillation. Among 6516 patients, 77% were male, the median age (quartile 1; quartile 3) was 70 (59; 79), and 57% achieved ROSC. In total, 5514 patients (85%) were defibrillated using LIFEPAK (ROSC: 56%) and 1002 patients (15%) were defibrillated using ZOLL (ROSC: 63%). Patients defibrillated using ZOLL had an increased adjusted odds ratio (aOR) for ROSC compared with LIFEPAK (aOR, 1.22 [95% CI, 1.04–1.43]). There was no significant difference in 30‐day mortality (aOR, 1.11 [95% CI, 0.95–1.30]). Patients without emergency medical services defibrillation, but treated by ZOLL‐equipped emergency medical services, had a nonsignificant aOR for ROSC compared with LIFEPAK (aOR, 1.10 [95% CI, 0.99–1.23]) and the difference‐in‐difference analysis was not statistically significant (OR, 1.10 [95% CI, 0.91–1.34]). Conclusions: Defibrillation using ZOLL X Series was associated with increased odds for ROSC compared with defibrillation using LIFEPAK 15 for patients with OHCA. However, a difference‐in‐difference analysis suggested that other factors may be responsible for the observed association.Keywords
This publication has 41 references indexed in Scilit:
- Association Between Number of Volunteer Responders and Interventions Before Ambulance Arrival for Cardiac ArrestJACC, 2023
- Smartphone Activation of Citizen Responders to Facilitate Defibrillation in Out-of-Hospital Cardiac ArrestJACC, 2020
- Defibrillation for Ventricular FibrillationJACC, 2017
- The Influence of Scenario-Based Training and Real-Time Audiovisual Feedback on Out-of-Hospital Cardiopulmonary Resuscitation Quality and Survival From Out-of-Hospital Cardiac ArrestAnnals of Emergency Medicine, 2013
- A comparison of rectilinear and truncated exponential biphasic waveforms in elective cardioversion of atrial fibrillation: A prospective randomized controlled trialResuscitation, 2013
- Multiple imputation using chained equations: Issues and guidance for practiceStatistics in Medicine, 2010
- Global incidences of out-of-hospital cardiac arrest and survival rates: Systematic review of 67 prospective studiesResuscitation, 2010
- A comparison of defibrillation efficacy between different impedance compensation techniques in high impedance porcine modelResuscitation, 2009
- Prospective, randomized comparison of two biphasic waveforms for the efficacy and safety of transthoracic biphasic cardioversion of atrial fibrillationHeart Rhythm, 2005
- Comparison of rectilinear biphasic waveform energy versus truncated exponential biphasic waveform energy for transthoracic cardioversion of atrial fibrillationThe American Journal of Cardiology, 2004