ZnO–CuO Core-Hollow Cube Nanostructures for Highly Sensitive Acetone Gas Sensors at the ppb Level
- 3 July 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (31) , 35688-35697
Abstract
This paper presents a ZnO-CuO p-n heterojunction chemiresistor sensor, which comprises CuO hollow nanocubes attached to ZnO spherical cores as active materials. These ZnO-CuO core-hollow cube nanostructures exhibit a remarkable response of 11.14 at 1 ppm acetone and 200 °C, which is a superior result to those reported by other metal-oxide-based sensors. The response can be measured up to 40 ppb, and the limit of detection is estimated as 9 ppb. ZnO-CuO core-hollow cube nanostructures also present high selectivity toward acetone against other volatile organic compounds and demonstrate excellent stability for up to 40 days. The outstanding gas sensing performance of the developed nanocubes is attributed to their uniform and unique morphology. Their core-shell-like structures allow the main charge transfer pathways to pass the interparticle p-p junctions, and the p-n junctions in each particle increase the sensitivity of the reactions to gas molecules. The small grain size and high surface area of each domain also enhance the surface gas adsorption.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2017M3A9F1033056, NRF-2018R1A2B3004096, NRF-2018R1A5A1025208)
- Ministry of Education, Science and Technology (2011-0031640)
This publication has 66 references indexed in Scilit:
- Selective Diagnosis of Diabetes Using Pt-Functionalized WO3 Hemitube Networks As a Sensing Layer of Acetone in Exhaled BreathAnalytical Chemistry, 2012
- Metal Oxide Nanostructures and Their Gas Sensing Properties: A ReviewSensors, 2012
- Vacancy-Mediated Magnetism in Pure Copper Oxide NanoparticlesDiscover Nano, 2010
- Gas sensors using hierarchical and hollow oxide nanostructures: OverviewSensors and Actuators B: Chemical, 2009
- Metal oxide-based gas sensor research: How to?Sensors and Actuators B: Chemical, 2007
- Effects of Copper Oxide/Gold Electrode as the Source-Drain Electrodes in Organic Thin-Film TransistorsElectrochemical and Solid-State Letters, 2007
- Breath Analysis: Potential for Clinical Diagnosis and Exposure AssessmentClinical Chemistry, 2006
- Determination of acetone in human breath by gas chromatography–mass spectrometry and solid-phase microextraction with on-fiber derivatizationJournal of Chromatography B, 2004
- Time variation of ammonia, acetone, isoprene and ethanol in breath: a quantitative SIFT-MS study over 30 daysPhysiological Measurement, 2003
- Reporting physisorption data for gas/solid systems with special reference to the determination of surface area and porosity (Recommendations 1984)Pure and Applied Chemistry, 1985