Probabilistic Risk Assessment of Grid-Scale Lithium-Ion Battery Energy Storage System Fire Hazards: Hydrogen Fluoride (HF) Toxicity, Suppression Effectiveness, and Comparative Compartment Design Analysis
Preprint
- 5 June 2026
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Battery Energy Storage Systems (BESS), utilizing chemistries based on Nickel Manganese Cobalt (NMC) containing lithium-ion devices, often present fire safety hazards that existing qualitative risk frameworks, including NFPA 855's 5×5 consequence-likelihood matrix, are insufficiently granular to quantify. This paper presents an original probabilistic risk assessment (PRA) of fire hazards associated with BESS for a 485.52 kWh NMC installation at the Equinix SG4-4A data centre in Singapore, using Monte Carlo simulation (N = 10,000 iterations) to characterise uncertainty in hydrogen fluoride (HF) gas dose, time to Immediately Dangerous to Life or Health (IDLH) concentration, cabinet-to-cabinet propagation probability, and suppression effectiveness. The HF yield is modelled as a triangular distribution (0.3–0.8 g/kWh, mode 0.5 g/kWh), ventilation activation delay as log-normal (median 90 s), and suppression effectiveness as a piecewise function of water application delay. HF dose exceeded the National Institute for Occupational Safety and Health (NIOSH) IDLH of 25 mg/m³ in 100% of simulated scenarios for both single- and two-compartment designs, confirming that HF toxicity is essentially present for any occupant during a full thermal runaway event and that ventilation alone cannot achieve adequate risk reduction. Single-stage suppression effectiveness was only 37.9% (mean), confirming that two-stage (clean agent + water) suppression is warranted for NMC chemistry. The two-compartment design reduced peak HF dose by 50% and reduced mean IDLH clearance time from 599 to 301 minutes, shifting residual risk from As Low As Reasonably Practicable (ALARP)-tolerable to broadly acceptable under UK Health and Safety Executive (HSE) criteria. The paper proposes a quantitative PRA framework as a complement to NFPA 855 Chapter 5's qualitative Hazard Mitigation Analysis. To the best of our knowledge, this is the first study to apply Monte Carlo simulation to HF dose modelling in a tropical data-centre BESS context, addressing a documented gap in the literature.Keywords
All Related Versions
This publication has 18 references indexed in Scilit:
- Experimental investigation of explosion hazard from lithium-ion battery thermal runaway effluent gasFuel, 2024
- Characterization of pristine and aged NMC lithium-ion battery thermal runaway using ARC experiments coupled with optical techniquesApplied Thermal Engineering, 2024
- Pyrolysis-based modelling of 18650-type lithium-ion battery fires in thermal runaway with LCO, LFP and NMC cathodesJournal of Power Sources, 2024
- Review of gas emissions from lithium-ion battery thermal runaway failure — Considering toxic and flammable compoundsJournal of Energy Storage, 2024
- Characterizing and predicting 21700 NMC lithium-ion battery thermal runaway induced by nail penetrationApplied Thermal Engineering, 2022
- Heat generation and thermal runaway of lithium-ion battery induced by slight overcharging cyclingJournal of Power Sources, 2022
- Incorporation of technical, human and organizational risks in a dynamic probabilistic fire risk model for high‐rise residential buildingsFire and Materials, 2020
- Systematic review of human and organizational risks for probabilistic risk analysis in high-rise buildingsReliability Engineering & System Safety, 2019
- Analyzing system safety in lithium-ion grid energy storageJournal of Power Sources, 2015
- A framework for risk evaluationJournal of Hazardous Materials, 1995