Hemodynamic Effect of Pulsatile on Blood Flow Distribution with VA ECMO: A Numerical Study
Open Access
- 20 September 2022
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 9 (10) , 487
Abstract
The pulsatile properties of arterial flow and pressure have been thought to be important. Nevertheless, a gap still exists in the hemodynamic effect of pulsatile flow in improving blood flow distribution of veno-arterial extracorporeal membrane oxygenation (VA ECMO) supported by the circulatory system. The finite-element models, consisting of the aorta, VA ECMO, and intra-aortic balloon pump (IABP) are proposed for fluid-structure interaction calculation of the mechanical response. Group A is cardiogenic shock with 1.5 L/min of cardiac output. Group B is cardiogenic shock with VA ECMO. Group C is added to IABP based on Group B. The sum of the blood flow of cardiac output and VA ECMO remains constant at 4.5 L/min in Group B and Group C. With the recovery of the left ventricular, the flow of VA ECMO declines, and the effective blood of IABP increases. IABP plays the function of balancing blood flow between left arteria femoralis and right arteria femoralis compared with VA ECMO only. The difference of the equivalent energy pressure (dEEP) is crossed at 2.0 L/min to 1.5 L/min of VA ECMO. PPI’ (the revised pulse pressure index) with IABP is twice as much as without IABP. The intersection with two opposing blood generates the region of the aortic arch for the VA ECMO (Group B). In contrast to the VA ECMO, the blood intersection appears from the descending aorta to the renal artery with VA ECMO and IABP. The maximum time-averaged wall shear stress (TAWSS) of the renal artery is a significant difference with or not IABP (VA ECMO: 2.02 vs. 1.98 vs. 2.37 vs. 2.61 vs. 2.86 Pa; VA ECMO and IABP: 8.02 vs. 6.99 vs. 6.62 vs. 6.30 vs. 5.83 Pa). In conclusion, with the recovery of the left ventricle, the flow of VA ECMO declines and the effective blood of IABP increases. The difference between the equivalent energy pressure (EEP) and the surplus hemodynamic energy (SHE) indicates the loss of pulsation from the left ventricular to VA ECMO. 2.0 L/min to 1.5 L/min of VA ECMO showing a similar hemodynamic energy loss with the weak influence of IABP.Keywords
Funding Information
- National Natural Science Foundation of China (11902006, 2018M640030)
- Postdoctoral Research Foundation of China (11902006, 2018M640030)
This publication has 54 references indexed in Scilit:
- Clinical outcome of mechanical circulatory support for refractory cardiogenic shock in the current eraThe Journal of Heart and Lung Transplantation, 2013
- Evolution of the Extracorporeal Life Support CircuitryArtificial Organs, 2010
- Renal and Hepatic Function Improve in Advanced Heart Failure Patients During Continuous-Flow Support With the HeartMate II Left Ventricular Assist DeviceCirculation, 2009
- Is Pulsatile Blood Flow No Longer Essential?Circulation, 2009
- Paracorporeal pulsatile biventricular assist device versus extracorporal membrane oxygenation–extracorporal life support in adult fulminant myocarditisThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Review Article: Comparison of perfusion modes on microcirculation during acute and chronic cardiac support: is there a difference?Perfusion, 2007
- Intraaortic Balloon Pumping During Cardioplegic Arrest Preserves Lung Function in Patients With Chronic Obstructive Pulmonary DiseaseThe Annals of Thoracic Surgery, 2006
- Relationship between outcome and baseline blood pressure and other haemodynamic measures in acute ischaemic stroke: data from the TAIST trialJournal Of Hypertension, 2006
- Renal Circulation and Cellular Metabolism During Left Ventricular Assisted Circulation: Comparison Study of Pulsatile and Nonpulsatile AssistsArtificial Organs, 1997
- Energy Equivalent PressureArchives of Surgery, 1966