Abstract
A key to the analysis of function after total hip replacement (THR) is the ability to identify gait adaptations specific to design features and surgical procedures. In a randomised controlled design, we evaluated the mechanics of gait after THR with a hip resurfacing system or conventional prosthesis. We also investigated whether gait adaptations returned to normal postoperatively. Similar improvements in mechanics of gait were found, except for peak abductor moments, which improved more in the conventional group. Gait speed increased significantly, but with no differences between groups. The increase in walking speed was reflected as significant improvement within groups in most kinematic and kinetic variables. Significant differences between the operated and non-operated hip were seen in all patients, but with no difference between groups. Mean curves of joint angle profiles and moments in all anatomical planes during a gait cycle revealed that gait impairment persisted with no differences between the conventional prosthesis and the resurfacing system.Keywords
This publication has 27 references indexed in Scilit:
- Sports after Hip Resurfacing ArthroplastyThe American Journal of Sports Medicine, 2007
- Preoperative gait adaptations persist one year after surgery in clinically well-functioning total hip replacement patientsJournal of Biomechanics, 2007
- Biomechanics of the Birmingham hip resurfacing arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2006
- Biomechanical reconstruction of the hipThe Journal of Bone and Joint Surgery. British volume, 2006
- Recovery of walking speed and symmetrical movement of the pelvis and lower extremity joints after unilateral THAJournal of Biomechanics, 2004
- A gait analysis data collection and reduction techniqueHuman Movement Science, 1991
- Measurement of lower extremity kinematics during level walkingJournal of Orthopaedic Research, 1990
- Hip function after total vs. surface replacementActa Orthopaedica, 1985
- Joint Function after Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1981