Resolution of Ofloxacin–Ciprofloxacin and Ofloxacin–Norfloxacin Binary Mixtures by Flow-Injection Chemiluminescence in Combination with Partial Least Squares Multivariate Calibration
- 19 June 2007
- journal article
- research article
- Published by Springer Nature in Journal of Fluorescence
- Vol. 17 (5) , 481-491
Abstract
A flow-injection chemiluminescence (CL) method is described for the determination of ciprofloxacin (CIP), norfloxacin (NOR) and ofloxacin (OFL), commonly used antibiotics of the fluoroquinolones family. The method is based on the CL reaction of the fluoroquinolones with tris(2,2′-bipyridyl) ruthenium(II) and Ce (IV), in sulfuric acid medium. The maximum CL emission, given at 0.45 min for CIP, at 0.35 min for NOR and at 0.04 min for OFL, respectively, were measured, allowing the simple application of the proposed method to the routine analysis of the antibiotics. The methods were applied to the determination of CIP, NOR and OFL, in several pharmaceutical preparations, with very satisfactory results, and validated by a previously reported HPLC method. The time-resolved equipment allowed the measurement of the kinetic evolution of the chemiluminescence signals. In base to the differences in the kinetic behaviour of ofloxacin with respect to ciprofloxacin and norfloxacin, binary mixtures of the drugs were resolved by using the time-resolved chemiluminescence signals, in combination with first-order partial least-squares (PLS) multivariate calibration.Keywords
This publication has 51 references indexed in Scilit:
- Molecular Imprinting-Chemiluminescence Determination of Norfloxacin Using a Norfloxacin-Imprinted Polymer as the Recognition MaterialMicrochimica Acta, 2005
- Time-resolved chemiluminescence: a novel tool for improved emission sequence in stopped-flow analysisAnalytica Chimica Acta, 2004
- Simple, rapid determination of enrofloxacin and ciprofloxacin in bovine milk and plasma by high-performance liquid chromatography with fluorescence detectionJournal of Pharmaceutical and Biomedical Analysis, 2004
- Validation of bias in multianalyte determination methods.Analytica Chimica Acta, 2000
- Analytical applications of tris(2,2′-bipyridyl)ruthenium(III) as a chemiluminescent reagentAnalytica Chimica Acta, 1999
- Development of Electrogenerated Chemiluminescence HPLC for Ofloxacin Using Tris (2, 2′-bipyridine) ruthenium (II) and Its Application to Residual Analysis in Chicken TissuesFood Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi), 1999
- Chemiluminescence flow-injection analysis of captopril applying a sensitized rhodamine 6G methodJournal of Pharmaceutical and Biomedical Analysis, 1996
- Spectrophotometric and spectrofluorimetric estimation of ciprofloxacin and norfloxacin by ternary complex formation with eosin and palladium(II)Journal of Pharmaceutical and Biomedical Analysis, 1996
- Performance of the stopped-flow technique in chemiluminescence spectrometry based on direct rate measurementsAnalytica Chimica Acta, 1989
- Chemiluminescence from Reduction ReactionsJournal of the American Chemical Society, 1966