Abstract
This study aims to evaluate the daylighting performance of double-skin façades (DSF) incorporating cobogó panels, considering different perforation rates (20%, 50%, and 80%) and materials (fiber cement, wood, and steel) in a subtropical climate. The methodology is based on computational simulations conducted using Rhinoceros 3D, Grasshopper, and associated plugins, employing climate data from São Paulo and analysis through the sDA300/50% metric. The results demonstrated that the perforation rate is the primary influencing factor, with a significant increase in daylight autonomy as façade permeability increases. Conversely, at low perforation levels, performance proved insufficient, particularly on lower floors. The material showed a secondary influence, with a slight advantage observed for steel. The study highlights the potential of using cobogó elements in the outer layer of double-skin façades to enhance daylighting performance, emphasizing the importance of façade geometry in luminous performance.