Abstract
A multi-bus MG normally bridge multiple DC buses via a complex line impedance network. This intricate configuration together with tickling constant power loads (CPLs) may cause severe stability issues. For system stability improvement, a novel uniform nonsmooth control scheme (UNCS) is proposed. UNCS has the following four-fold advantages. 1) UNCS helps to express commonly used DC/DC converters, boost, buck and buck-boost, into a uniform model. The model substantially facilitates a uniform stabilizer design that accommodate the preceding three converters despite their typology differences. 2) UNCS assigns each converter based distributed generator (DG) with a composite large signal stabilizer comprising a nonsmooth observer and a nonsmooth controller. 3) The stabilizer also provides an additional control degree of freedom, a fine-tuning factor, to refine DG dynamic responses to meet high requirements for voltage and power qualities. 4) When numerous DGs with the proposed stabilizer assembles to build a multi-bus MG, the overall system large signal stabilization is autonomously attained without communication links, which is mathematically justified by Lyapunov stability analyses. As such, DGs are allowed to randomly plug in/out without worrying about vitiating system level stability. Experiments show that UNCS will stabilize the multi-bus MG in a large operation range.
Funding Information
  • Program for Professor of Special Appointment (Eastern Scholar) at Shanghai Institutions of Higher Learning
  • Natural Science Foundation of Shanghai Municipality (19ZR1420500)
  • Renewable Energy Integration Demonstrator-Singapore
  • Energy Research Institute, Nanyang Technological University

This publication has 25 references indexed in Scilit: