Application of AXUV diode detectors at ASDEX Upgrade
Authors:
- 1 March 2014
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (3) , 033503
Abstract
In the ASDEX Upgrade tokamak, a radiation measurement for a wide spectral range, based on semiconductor detectors, with 256 lines of sight and a time resolution of 5μs was recently installed. In combination with the foil based bolometry, it is now possible to estimate the absolutely calibrated radiated power of the plasma on fast timescales. This work introduces this diagnostic based on AXUV (Absolute eXtended UltraViolet) n-on-p diodes made by International Radiation Detectors, Inc. The measurement and the degradation of the diodes in a tokamak environment is shown. Even though the AXUV diodes are developed to have a constant sensitivity for all photon energies (1 eV-8 keV), degradation leads to a photon energy dependence of the sensitivity. The foil bolometry, which is restricted to a time resolution of less than 1 kHz, offers a basis for a time dependent calibration of the diodes. The measurements of the quasi-calibrated diodes are compared with the foil bolometry and found to be accurate on the kHz time scale. Therefore, it is assumed, that the corrected values are also valid for the highest time resolution (200 kHz). With this improved diagnostic setup, the radiation induced by edge localized modes is analyzed on fast timescales.Keywords
This publication has 28 references indexed in Scilit:
- Optimization of a bolometer detector for ITER based on Pt absorber on SiN membraneReview of Scientific Instruments, 2010
- Radiation distributions in TCVJournal of Nuclear Materials, 2007
- Evolution of Filament Structures during Edge-Localized Modes in the MAST TokamakPhysical Review Letters, 2006
- Prototype of a radiation hard resistive bolometer for ITERPlasma Physics and Controlled Fusion, 2005
- ELM-induced plasma transport in the DIII-D SOLJournal of Nuclear Materials, 2005
- Time resolved radiated power during tokamak disruptions and spectral averaging of AXUV photodiode response in DIII-DReview of Scientific Instruments, 2004
- Nonaxisymmetric Energy Deposition Pattern on ASDEX Upgrade Divertor Target Plates during Type-I Edge-Localized ModesPhysical Review Letters, 2003
- High resolution bolometry on the Alcator C-Mod tokamak (invited)Review of Scientific Instruments, 1999
- Characterization of photodiodes as transfer detector standards in the 120 nm to 600 nm spectral rangeMetrologia, 1998
- Stable silicon photodiodes for absolute intensity measurements in the VUV and soft X-ray regionsJournal of Electron Spectroscopy and Related Phenomena, 1996