Effect of Pulsatility on the Mathematical Modeling of Rotary Blood Pumps
- 27 July 2011
- journal article
- Published by Wiley in Artificial Organs
- Vol. 35 (8) , 825-832
Abstract
In this study, the effect of time derivatives of flow rate and rotational speed was investigated on the mathematical modeling of a rotary blood pump (RBP). The basic model estimates the pressure head of the pump as a dependent variable using measured flow and speed as predictive variables. Performance of the model was evaluated by adding time derivative terms for flow and speed. First, to create a realistic working condition, the Levitronix CentriMag RBP was implanted in a sheep. All parameters from the model were physically measured and digitally acquired over a wide range of conditions, including pulsatile speed. Second, a statistical analysis of the different variables (flow, speed, and their time derivatives) based on multiple regression analysis was performed to determine the significant variables for pressure head estimation. Finally, different mathematical models were used to show the effect of time derivative terms on the performance of the models. In order to evaluate how well the estimated pressure head using different models fits the measured pressure head, root mean square error and correlation coefficient were used. The results indicate that inclusion of time derivatives of flow and speed can improve model accuracy, but only minimally.Keywords
This publication has 19 references indexed in Scilit:
- The Importance of dQ/dt on the Flow Field in a Turbodynamic Pump With Pulsatile FlowArtificial Organs, 2009
- Left Ventricle Load Impedance Control by Apical VAD Can Help Heart Recovery and Patient Perfusion: A Numerical StudyASAIO Journal, 2007
- Third‐generation Blood Pumps With Mechanical Noncontact Magnetic BearingsArtificial Organs, 2006
- Rotary Blood Pumps for Cardiac Assistance: A “Must”?Artificial Organs, 2004
- Non-invasive flow estimation in an implantable rotary blood pump: a study considering non-pulsatile and pulsatile flowsPhysiological Measurement, 2003
- Modeling and Control of a Brushless DC Axial Flow Ventricular Assist DeviceASAIO Journal, 2002
- Investigation of fluid dynamics within a miniature mixed flow blood pumpExperiments in Fluids, 2001
- Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist deviceThe Annals of Thoracic Surgery, 1999
- Reversal of Chronic Ventricular Dilation in Patients With End-Stage Cardiomyopathy by Prolonged Mechanical UnloadingCirculation, 1995
- A new look at the statistical model identificationIEEE Transactions on Automatic Control, 1974