A novel approach for monitoring of cyanobacterial toxins: development and evaluation of the passive sampler for microcystins
- 28 December 2007
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 390 (4) , 1167-1172
Abstract
We have investigated the ability of an integrative sampler for polar organic chemicals to sequestrate a group of common and highly hazardous cyanobacterial toxins—microcystins. In a pilot experiment, commercially available passive samplers were shown to effectively accumulate microcystins after 7 days’ exposure in the field. To find the most efficient configuration for sequestration of microcystins, four different porous membranes (polycarbonate, polyester, polyethersulfone and nylon) and two sorbents (Oasis HLB and Bondesil-LMS) were evaluated in the laboratory experiments, where samplers of different configuration were exposed to microcystins (microcystin-RR and microcystin-LR) for 14 days under steady conditions. We observed differences in sampling rates and amounts of accumulated microcystins depending on the sampler configurations. The samplers constructed with the polycarbonate membrane and Oasis HLB sorbent (2.75 mg/cm2) provided the highest sampling rates (0.022 L/day for microcystin-RR and 0.017 L/day for microcystin-LR). To the best of our knowledge, the present study is the first reporting application of passive samplers for microcystins, and our results demonstrate the suitability of this tool for monitoring cyanotoxins in water.Keywords
This publication has 20 references indexed in Scilit:
- Passive air sampler as a tool for long-term air pollution monitoring: Part 1. Performance assessment for seasonal and spatial variationsEnvironmental Pollution, 2006
- Passive sampling techniques for monitoring pollutants in waterTrAC Trends in Analytical Chemistry, 2005
- Occurrence and elimination of cyanobacterial toxins in drinking water treatment plantsToxicology and Applied Pharmacology, 2005
- Contamination of drinking water in the Czech Republic by microcystinsArchiv für Hydrobiologie, 2003
- Peer Reviewed: Equilibrium Sampling DevicesEnvironmental Science & Technology, 2003
- Detection of microcystins with protein phosphatase inhibition assay, high-performance liquid chromatography–UV detection and enzyme-linked immunosorbent assayAnalytica Chimica Acta, 2002
- SIMULTANEOUS DETERMINATION OF THE CYANOTOXINS ANATOXIN A, MICROCYSTIN DESMETHYL-3, LR, RR, AND YR IN FISH MUSCLE USING LIQUID CHROMATOGRAPHY-MASS SPECTROMETRYJournal of Liquid Chromatography & Related Technologies, 2000
- Chromatography of microcystinsAnalytica Chimica Acta, 1997
- The Cyanotoxins1997
- Cyanobacteria secondary metabolites—the cyanotoxinsJournal of Applied Bacteriology, 1992