Real-Time Improvement of Continuous Glucose Monitoring Accuracy
Open Access
- 14 March 2013
- journal article
- Published by American Diabetes Association in Diabetes Care
- Vol. 36 (4) , 793-800
Abstract
OBJECTIVE: Reliability of continuous glucose monitoring (CGM) sensors is key in several applications. In this work we demonstrate that real-time algorithms can render CGM sensors smarter by reducing their uncertainty and inaccuracy and improving their ability to alert for hypo- and hyperglycemic events. RESEARCH DESIGN AND METHODS: The smart CGM (sCGM) sensor concept consists of a commercial CGM sensor whose output enters three software modules, able to work in real time, for denoising, enhancement, and prediction. These three software modules were recently presented in the CGM literature, and here we apply them to the Dexcom SEVEN Plus continuous glucose monitor. We assessed the performance of the sCGM on data collected in two trials, each containing 12 patients with type 1 diabetes. RESULTS: The denoising module improves the smoothness of the CGM time series by an average of ∼57%, the enhancement module reduces the mean absolute relative difference from 15.1 to 10.3%, increases by 12.6% the pairs of values falling in the A-zone of the Clarke error grid, and finally, the prediction module forecasts hypo- and hyperglycemic events an average of 14 min ahead of time. CONCLUSIONS: We have introduced and implemented the sCGM sensor concept. Analysis of data from 24 patients demonstrates that incorporation of suitable real-time signal processing algorithms for denoising, enhancement, and prediction can significantly improve the performance of CGM applications. This can be of great clinical impact for hypo- and hyperglycemic alert generation as well in artificial pancreas devices.Keywords
This publication has 38 references indexed in Scilit:
- Artificial Pancreas: Past, Present, FutureDiabetes, 2011
- Sensor-augmented pump therapy lowers HbA1c in suboptimally controlled Type 1 diabetes; a randomized controlled trialDiabetic Medicine, 2011
- Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 DiabetesDiabetes Care, 2011
- Estimating Plasma Glucose from Interstitial Glucose: The Issue of Calibration Algorithms in Commercial Continuous Glucose Monitoring DevicesSensors, 2010
- “Smart” Continuous Glucose Monitoring Sensors: On-Line Signal Processing IssuesSensors, 2010
- Real-Time Hypoglycemia Prediction Suite Using Continuous Glucose MonitoringDiabetes Care, 2010
- Enhanced Accuracy of Continuous Glucose Monitoring by Online Extended Kalman FilteringDiabetes Technology & Therapeutics, 2010
- Statistical Tools to Analyze Continuous Glucose Monitor DataDiabetes Technology & Therapeutics, 2009
- Estimation of Future Glucose Concentrations with Subject-Specific Recursive Linear ModelsDiabetes Technology & Therapeutics, 2009
- Continuous Glucose Monitoring and Intensive Treatment of Type 1 DiabetesNew England Journal of Medicine, 2008