Optimal matrix size of chest radiographs for computer-aided detection on lung nodule or mass with deep learning
- 29 April 2020
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 30 (9) , 4943-4951
Abstract
Objectives To investigate the optimal input matrix size for deep learning-based computer-aided detection (CAD) of nodules and masses on chest radiographs. Methods We retrospectively collected 2088 abnormal (nodule/mass) and 352 normal chest radiographs from two institutions. Three thoracic radiologists drew 2758 abnormalities regions. A total of 1736 abnormal chest radiographs were used for training and tuning convolutional neural networks (CNNs). The remaining 352 abnormal and 352 normal chest radiographs were used as a test set. Two CNNs (Mask R-CNN and RetinaNet) were selected to validate the effects of the squared different matrix size of chest radiograph (256, 448, 896, 1344, and 1792). For comparison, figure of merit (FOM) of jackknife free-response receiver operating curve and sensitivity were obtained. Results In Mask R-CNN, matrix size 896 and 1344 achieved significantly higher FOM (0.869 and 0.856, respectively) for detecting abnormalities than 256, 448, and 1792 (0.667–0.820) (p < 0.05). In RetinaNet, matrix size 896 was significantly higher FOM (0.906) than others (0.329–0.832) (p < 0.05). For sensitivity of abnormalities, there was a tendency to increase sensitivity when lesion size increases. For small nodules (< 10 mm), the sensitivities were 0.418 and 0.409, whereas the sensitivities were 0.937 and 0.956 for masses. Matrix size 896 and 1344 in Mask R-CNN and matrix size 896 in RetinaNet showed significantly higher sensitivity than others (p < 0.05). Conclusions Matrix size 896 had the highest performance for various sizes of abnormalities using different CNNs. The optimal matrix size of chest radiograph could improve CAD performance without additional training data. Key Points • Input matrix size significantly affected the performance of a deep learning-based CAD for detection of nodules or masses on chest radiographs. • The matrix size 896 showed the best performance in two different CNN detection models. • The optimal matrix size of chest radiographs could enhance CAD performance without additional training data.Keywords
Funding Information
- Ministry of Trade, Industry and Energy (10072064)
This publication has 14 references indexed in Scilit:
- Development and Validation of Deep Learning–based Automatic Detection Algorithm for Malignant Pulmonary Nodules on Chest RadiographsRadiology, 2019
- Review: On Segmentation of Nodules from Posterior and Anterior Chest RadiographsInternational Journal of Biomedical Imaging, 2018
- Mask R-CNN2017
- Discrimination of Breast Cancer with Microcalcifications on Mammography by Deep LearningScientific Reports, 2016
- Rethinking the Inception Architecture for Computer Vision2016
- Going deeper with convolutions2015
- Computer-aided Detection Improves Detection of Pulmonary Nodules in Chest Radiographs beyond the Support by Bone-suppressed ImagesRadiology, 2014
- Computer-aided diagnosis in chest radiography: Beyond nodulesEuropean Journal of Radiology, 2009
- A CAD System for Screening X-ray Chest Radiography2009
- The Coding of Roentgen Images for Computer Analysis as Applied to Lung CancerRadiology, 1963