High speed versus pulsed images for micro-particle image velocimetry: a direct comparison of red blood cells versus fluorescing tracers as tracking particles
Authors:
- 18 September 2013
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 34 (10) , 1363-1374
Abstract
High speed photography in micro-particle image velocimetry (μPIV) using red blood cells as tracer particles and the use of fluorescing tracer particles (in conjunction with pulsed images) are directly compared by using both methods simultaneously. Measurements are taken on the same blood sample in the same microchip using both methods. This work directly and statistically compares the two methods of μPIV measurement in a controlled in vitro environment for the first time in literature. The pulsed method using fluorescing tracer particles is found to decrease the depth of correlation as expected, and to better represent the shape of the velocity profile. Two methods of velocity characterization are used (single and double parameter) and the pulsed images provide better shape representation in both cases.Keywords
This publication has 25 references indexed in Scilit:
- Velocity measurement accuracy in optical microhemodynamics: experiment and simulationPhysiological Measurement, 2012
- Experimental Analysis of Microchannel Entrance Length Characteristics Using Microparticle Image VelocimetryJournal of Fluids Engineering, 2010
- Measurement of Individual Red Blood Cell Motions Under High Hematocrit Conditions Using a Confocal Micro-PTV SystemAnnals of Biomedical Engineering, 2009
- The deformation of flexible PDMS microchannels under a pressure driven flowLab on a Chip, 2008
- In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV systemBiomedical Microdevices, 2007
- In vitro confocal micro-PIV measurements of blood flow in a square microchannel: The effect of the haematocrit on instantaneous velocity profilesJournal of Biomechanics, 2007
- Confocal micro-PIV measurements of three-dimensional profiles of cell suspension flow in a square microchannelMeasurement Science and Technology, 2006
- Micro particle-image velocimetry of bead suspensions and blood flowsExperiments in Fluids, 2005
- Velocity pulse measurements in the mesenteric arterioles of rabbitsPhysiological Measurement, 2003
- Volume illumination for two-dimensional particle image velocimetryMeasurement Science and Technology, 2000