Design and Behavior of Enlarged End Flange (EEF) Steel Moment-Frame Connections
Authors:
- 1 August 2006
- journal article
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 9 (4) , 545-559
Abstract
The FEMA-350 indicates that the expected location of the plastic hinge for the frame beams with the Reduced Beam Section (RBS) connections is valid only for beams with gravity loads representing a small portion of the total flexural demand. In order to overcome the limitation of the gravity loads, the Enlarged End Flange (EEF) connection is proposed. In EEF connections, side plates are welded to the beam flanges near the beam ends. This paper presents a hand-calculated design example and the suggested connection details of a beam with the EEF connection. A study of the flexural strength and the interstory drift angular rotations of a total of five EEF beam-to-column connections, with beam sizes ranging from W24 × 94 up to W36 × 182, using the nonlinear static finite element approach is also summarized in this paper. The study concludes that the EEF connection is recommended for use in an ordinary moment frame system with wide bay widths.Keywords
This publication has 3 references indexed in Scilit:
- Panel Zone Yielding in Steel Moment ConnectionsEngineering Journal, 2000
- Experimental Investigation of Dogbone Moment ConnectionsEngineering Journal, 1998
- Ultimate Strength Considerations for Seismic Design of the Reduced Beam Section (Internal Plastic Hinge)Engineering Journal, 1997