Performance Evaluation of Novel Concentrating Photovoltaic Thermal Solar Collector under Quasi-Dynamic Conditions
Open Access
Abstract
Concentrating Photovoltaic Thermal (CPVT) collectors are suitable for integration in limited roof space due to their higher solar conversion efficiency. Solar sunlight can be used more effectively by CPVT collectors in comparison to individual solar thermal collectors or PV modules. In this study, the experimental investigation of a novel CPVT collector called a PC (power collector) has been carried out in real outdoor conditions, and the test set-up has been designed based on ISO 9806:2013. A quasi-dynamic testing method has been used because of the advantages that this method can offer for collectors with a unique construction, such as the proposed collector, over the steady-state testing method. With a quasi-dynamic testing method, it is possible to characterize the collector within a wide range of incidence angles and a complex incidence angle modifier profile. The proposed novel collector has a gross area of 2.57 m2. A maximum power output per collector unit area of 1140 W is found at 0 °C reduced temperature (1000 W/m2 irradiance level), while at a higher reduced temperature (70 °C), it drops down to 510 W for the same irradiance level. The data have been fitted through a multiple linear regression method, and the obtained efficiency curve coefficients are 0.39, 0.192, 1.294, 0.023, 0.2, 0, −5929 and 0 for Kθd, b0, c1, c2, c3, c4, c5 and c6, respectively. The experimental characterization carried out on the collector proved that the output powers calculated by using the obtained parameters of the quasi-dynamic testing method are in good agreement with experimental points.Keywords
Funding Information
- European Commission (101000785, 814865, 2020-1-TR01-KA202-093467)
- European Commission (101000785, 814865, 2020-1-TR01-KA202-093467)
- European Commission (101000785, 814865, 2020-1-TR01-KA202-093467)
This publication has 50 references indexed in Scilit:
- An experimental analysis of illumination intensity and temperature dependency of photovoltaic cell parametersApplied Energy, 2013
- Review of R&D progress and practical application of the solar photovoltaic/thermal (PV/T) technologiesRenewable and Sustainable Energy Reviews, 2012
- Testing of Solar Thermal Collectors Under Transient ConditionsEnergy Procedia, 2012
- Performance investigation and optimization of the Trough Concentrating Photovoltaic/Thermal systemSolar Energy, 2011
- Influence of Measurement Equipment on the Uncertainty of Performance Data from Test Loops for Concentrating Solar CollectorsJournal of Solar Energy Engineering, 2010
- Contributions to accelerating atmospheric CO 2 growth from economic activity, carbon intensity, and efficiency of natural sinksProceedings of the National Academy of Sciences of the United States of America, 2007
- Evaluation of CPC-collector designs for stand-alone, roof- or wall installationSolar Energy, 2005
- Design and simulation of a low concentrating photovoltaic/thermal systemEnergy Conversion and Management, 2005
- Efficiency test of solar collectors: uncertainty in the estimation of regression parameters and sensitivity analysisEnergy Conversion and Management, 2002
- Performance analyses of combined heating and photovoltaic power systems for residencesEnergy Conversion, 1976