A statistical analysis of the Bloch–SiegertB1mapping technique
- 31 July 2013
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (16) , 5673-5691
Abstract
A number of B1 mapping methods have been introduced. A model to facilitate choice among these methods is valuable, as the performance of each technique is affected by a variety of factors, including acquisition signal-to-noise ratio (SNR). The Bloch-Siegert shift B1 mapping method has recently garnered significant interest. In this paper, we present a statistical model suitable for analysis of the Bloch-Siegert shift method. Unlike previously presented models, the analysis is valid in both low SNR and high SNR regimes. We present a detailed analysis of the performance of the Bloch-Siegert shift B1 mapping method across a broad range of acquisition scenarios, and compare it to two other B1 mapping techniques (the dual angle method and the phase sensitive method). Further validation of the model is presented through both Monte Carlo simulations and experimental results. The simulations and experimental results match the model well, lending confidence to its accuracy. Each technique is found to perform well with high acquisition SNR. However, our results suggest that the dual angle method is not reliable in low SNR environments. Furthermore, the phase sensitive method appears to outperform the Bloch-Siegert shift method in these low-SNR cases, although variations of the Bloch-Siegert method may be possible that improve its performance at low SNR.Keywords
This publication has 20 references indexed in Scilit:
- Phase‐sensitive sodium B1 mappingMagnetic Resonance in Medicine, 2010
- An analysis of the accuracy of magnetic resonance flip angle measurement methodsPhysics in Medicine & Biology, 2010
- B1 mapping by Bloch‐Siegert shiftMagnetic Resonance in Medicine, 2010
- A phase‐sensitive method of flip angle mappingMagnetic Resonance in Medicine, 2008
- Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequencesPhysics in Medicine & Biology, 2008
- Designing multichannel, multidimensional, arbitrary flip angle RF pulses using an optimal control approachMagnetic Resonance in Medicine, 2008
- Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency fieldMagnetic Resonance in Medicine, 2006
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- Parallel excitation with an array of transmit coilsMagnetic Resonance in Medicine, 2004
- The Effect of Phase Error on DPSK Error ProbabilityIEEE Transactions on Communications, 1981