FATIGUE CRACK CLOSURE MEASUREMENTS ON 2024‐T3 SHEET SPECIMENS
Authors:
- 1 September 1995
- journal article
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 18 (9) , 917-921
Abstract
A computer‐controlled procedure has been developed for automatic measurement of the crack opening stress Sop during fatigue tests. A crack opening displacement gauge (COD meter) is used to obtain digital data on the load versus COD curves. Three methods for deriving Sop from the data sets are compared (1) a slope method, (2) a tangent lines intersecting method, and (3) a tangent point method. The effect of the position of the COD meter with respect to the crack tip on Sop is studied in tests of 2024‐T3 specimens. Results of crack growth and Sop are presented for CA loading with an overload, and with an overload followed by an underload.Keywords
This publication has 4 references indexed in Scilit:
- A Method for Determining Crack Opening Load from Load-Displacement Data1988
- A Comparison of Measurement Methods and Numerical Procedures for the Experimental Characterization of Fatigue Crack Closure1988
- Fatigue Crack Closure: Observations and Technical Significance1988
- The Significance of Fatigue Crack Closure1971