Abstract
Background and Objectives: A reliable method to eradicate the bacteria of residual carious dentin has not yet been developed. The aim of this study was to evaluate the antibacterial effect of a diode laser on Streptococcus mutans through different thickness (500, 1,000, and 2,000 µm) of human dentin. The thermal effect of laser irradiation was also investigated.Study Design/Materials and Methods: Dentin specimens were inoculated with 2 µl of S. mutans on one side and irradiated by a diode laser on the other side with a power output ranging from 0.5 to 7 W. The laser tip was swept with the whole irradiation area of 7 mm×3 mm at a speed of about 10 mm/second with a total irradiation time of 30 seconds. Cooling with distilled water (30 ml/minute) was applied simultaneously during laser irradiation. After laser irradiation, the bacteria was removed from the dentin surfaces and cultured for 48 hours at 37°C anaerobically to assess the colony forming units (CFU) per ml. The morphology of the lased bacteria and the temperature rise during laser irradiation were observed by scanning electron microscope (SEM) and measured by thermocouple, respectively.Results: The results revealed that 7 W of laser power could kill 97.7% of CFU through 500 µm thickness of dentin. However, the bactericidal efficiency was significantly reduced as the dentin thickness was increased. The morphological changes of lased bacteria ranged from less affected such as loss of their wall bands and existence of minicells to more severely degenerated, such as disintegration and fusion of cells with pores on the cell wall. Only the dentin specimens with a thickness of 500 µm exhibited a temperature rise greater than 5.5°C after receiving 5 or 7 W of laser irradiation.Conclusions: A diode laser can eliminate the Streptococcus mutans of the residual carious dentin without inducing high pulpal temperature rise when the remaining dentin thickness is greater than 1 mm. Lasers Surg. Med. 38:62–69, 2006.Keywords
This publication has 30 references indexed in Scilit:
- Antibacterial properties of aged dental cements evaluated by direct-contact and agar diffusion testsThe Journal of Prosthetic Dentistry, 2005
- Bactericidal effect of different laser systems in the deep layers of dentinLasers in Surgery and Medicine, 2004
- Evaluation of bacterial adhesion of Streptococcus mutans on dental restorative materialsBiomaterials, 2004
- Effect of Dentin on the Antibacterial Activity of Dentin Bonding AgentsJournal of Endodontics, 2004
- Bactericidal Effect of a 980-nm Diode Laser in the Root Canal Wall Dentin of Bovine TeethJournal of Clinical Laser Medicine & Surgery, 2004
- The residual caries dilemmaCommunity Dentistry and Oral Epidemiology, 1999
- The reasons for replacement and the age of failed restorations in general dental practiceActa Odontologica Scandinavica, 1997
- Irradiation of infected root canals with a diode laser in vivo: Results of microbiological examinationsLasers in Surgery and Medicine, 1997
- Role of Micro-organisms in Caries EtiologyJournal of Dental Research, 1994
- Location of Streptococcus mutans in the Dentinal Tubules of Open Infected Root CanalsJournal of Dental Research, 1980