Role of SAM Chain Length in Enhancing the Sensitivity of Nanopillar Modified Electrodes for Glucose Detection
Open Access
- 26 February 2009
- Vol. 9 (3) , 1295-1305
Abstract
In this report, alkanethiol self assembled monolayers (SAM) with two different chain lengths were used to immobilize the functionalizing enzyme (glucose oxidase) onto gold nanopillar modified electrodes and the electrochemical processes of these functionalized electrodes in glucose detection were investigated. First, the formation of these SAMs on the nanopillar modified electrodes was characterized by the cyclic voltammetry and electrochemical impedance spectroscopy techniques, and then the detection sensitivity of these functionalized electrodes to glucose was evaluated by the amperometry technique. Results showed that the SAM of alkanethiols with a longer chain length resulted in a higher degree of surface coverage with less defect and a higher electron transfer resistance, whereas the SAM of alkanethiols with a shorter chain length gave rise to a higher detection sensitivity to glucose. This study sheds some new insight into how to enhance the sensing performance of nanopillar modified electrodes.Keywords
This publication has 21 references indexed in Scilit:
- Optimizing the functionalization process for nanopillar enhanced electrodes with GOx/PPY for glucose detectionNanotechnology, 2008
- Electrochemical fabrication and evaluation of highly sensitive nanorod-modified electrodes for a biotin/avidin systemBiosensors and Bioelectronics, 2008
- Role of reaction kinetics and mass transport in glucose sensing with nanopillar array electrodesJournal of Biological Engineering, 2007
- Impedance spectral studies of self-assembly of alkanethiols with different chain lengths using different immobilization strategies on Au electrodesAnalytica Chimica Acta, 2005
- Glucose oxidase entrapped in polypyrrole on high-surface-area Pt electrodes: a model platform for sensitive electroenzymatic biosensorsJournal of Electroanalytical Chemistry, 2005
- Droplet-based microfluidic lab-on-a-chip for glucose detectionAnalytica Chimica Acta, 2004
- Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrodeJournal of Electroanalytical Chemistry, 2002
- The Influence of the Underlying Gold Substrate on Glucose Oxidase Electrodes Fabricated Using Self-Assembled MonolayersElectroanalysis, 2001
- Chemiluminescence flow sensor for in vivo on-line monitoring of glucose in awake rabbit by microdialysis samplingAnalytica Chimica Acta, 2001
- Design and development of a miniaturised total chemical analysis system for on-line lactate and glucose monitoring in biological samplesAnalytica Chimica Acta, 1997