Combined Contactless Conductometric, Photometric, and Fluorimetric Single Point Detector for Capillary Separation Methods
- 4 December 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (1) , 129-135
Abstract
This work for the first time combines three on-capillary detection methods, namely, capacitively coupled contactless conductometric (C4D), photometric (PD), and fluorimetric (FD), in a single (identical) point of detection cell, allowing concurrent measurements at a single point of detection for use in capillary electrophoresis, capillary electrochromatography, and capillary/nanoliquid chromatography. The novel design is based on a standard 6.3 mm i.d. fiber-optic SMA adapter with a drilled opening for the separation capillary to go through, to which two concentrically positioned C4D detection electrodes with a detection gap of 7 mm were added on each side acting simultaneously as capillary guides. The optical fibers in the SMA adapter were used for the photometric signal (absorbance), and another optical fiber at a 45° angle to the capillary was applied to collect the emitted light for FD. Light emitting diodes (255 and 470 nm) were used as light sources for the PD and FD detection modes. LOD values were determined under flow-injection conditions to exclude any stacking effects: For the 470 nm LED limits of detection (LODs) for FD and PD were for fluorescein (1 × 10−8 mol/L) and tartrazine (6 × 10−6 mol/L), respectively, and the LOD for the C4D was for magnesium chloride (5 × 10−7 mol/L). The advantage of the three different detection signals in a single point is demonstrated in capillary electrophoresis using model mixtures and samples including a mixture of fluorescent and nonfluorescent dyes and common ions, underivatized amino acids, and a fluorescently labeled digest of bovine serum albumin.Keywords
This publication has 46 references indexed in Scilit:
- Capillary electrophoresis-based methods for the determination of lipids—A reviewAnalytica Chimica Acta, 2008
- Determination of Maleic Hydrazide in Potato Samples Using Capillary Electrophoresis with Dual Detection (UV‐Electrochemical)Electroanalysis, 2008
- A review of the recent achievements in capacitively coupled contactless conductivity detectionAnalytica Chimica Acta, 2008
- Comparison of Different Contactless Conductivity Detectors for the Determination of Small Inorganic Ions by Capillary ElectrophoresisElectroanalysis, 2006
- Integrated Light Collimating System for Extended Optical-Path-Length Absorbance Detection in Microchip-Based Capillary ElectrophoresisAnalytical Chemistry, 2005
- Improved dual photometric-contactless conductometric detector for capillary electrophoresisAnalytica Chimica Acta, 2004
- Miniaturized capillary electrophoresis system with ultraviolet photometric detection combined with flow injection sample introduction using a modified falling-drop interfaceAnalytica Chimica Acta, 2004
- Enhanced UV-Visible Absorbance Detection in Capillary Electrophoresis Using Modified T-Shaped Post-Column Flow CellBulletin of the Korean Chemical Society, 2002
- Dual photometric-contactless conductometric detector for capillary electrophoresisAnalytica Chimica Acta, 2001
- Field-portable capillary electrophoresis instrument with potentiometric and amperometric detectionAnalytica Chimica Acta, 1999